Search results

  1. T

    Changing old boiler timer with a wireless thermostat - IMM24

    I have just rewired the old timer switch back in and it all comes on... I was worried that I had done something stupid and blown a fuse LOL so basically... the old one has 2 red wires that come out the back of it... one sleeved and one not, that go somewhere... when the switch is set to ON...
  2. T

    Changing old boiler timer with a wireless thermostat - IMM24

    Hi all I would like to swap out the old analogue timer switch, with a digital timer with wireless stat there is no house thermostat currently in the house. if the heating is scheduled to come on, the house just keep heating and heating, until the in-line stat on the boiler itself (out in the...
  3. T

    oil burner cutting out after 30 seconds after oil fill

    boiler is a Clyde Climatic 30 (not a combi) hi all I hope you are well and hope you can help me I moved to this house 3 months ago and all has been well with the heating. the oil got very low in the tank last week so ordered a fill which was delivered today. turned the heating on, and it...
  4. T

    Replacing 80's heating timer (dial) with wireless

    Ok that wiring will be a challenge. Definitely will hold off. .. but thank you
  5. T

    Replacing 80's heating timer (dial) with wireless

    looks like 20 min job for the plumber then... drain system, split pipe, install... then get sparky to wire it in...
  6. T

    Replacing 80's heating timer (dial) with wireless

    cheers Stem, did not see your reply there before I replied... I might have to invest in one of those at some point but after the renovation I am fast running out of funds LOL I guess the plumber would know at which point in the system, this would most likely need to go... as I have no clue...
  7. T

    Replacing 80's heating timer (dial) with wireless

    hmm suspect you are right there :-( the pipes go into the roof space, and into the ground... so not sure where they go from there.. I have had thermostatic valves fitted to all of the radiators, so at least I can stop the heating in the summer cooking the rooms, but I would still have the...
  8. T

    RSJ vs concrete lintel - 8foot span

    thanks for all the help and advice guys....
  9. T

    RSJ vs concrete lintel - 8foot span

    could always go 178 x 102 x 19kg
  10. T

    RSJ vs concrete lintel - 8foot span

    I like your thinking haa haa....
  11. T

    RSJ vs concrete lintel - 8foot span

    that's great, thank you so much for that description. every day is a learning day they say!
  12. T

    RSJ vs concrete lintel - 8foot span

    out of interest, how does the engineer calculate it? i.e. without the original design of the house? it must be a bit of a dark art, as the roof is supported by the main roof structure itself, which is supported by the outside and inside walls. this set of beams then also support it along the...
  13. T

    Replacing 80's heating timer (dial) with wireless

    hi there... I am pretty sure this is it...
  14. T

    RSJ vs concrete lintel - 8foot span

    in that side-long picture of the house I drew above, I have the i-beam going the length of the house, but in fact it terminates on this wall, and a wooden beam is used for the other half of the house...
  15. T

    RSJ vs concrete lintel - 8foot span

    thank you so much for the reply. I think the way to go is steel, as it takes more risk out of it and like you said finishing it is not that bigger deal. the problem is, I had it all right in my head until the builder came around and muddied my brain a little. his intentions were great of...
  16. T

    Replacing 80's heating timer (dial) with wireless

    I wonder is there a similar unit to the one I bought, that has additional settings... where I can say "on at this time no matter hat the temp is" or something like that... hmmm thinking...
  17. T

    Replacing 80's heating timer (dial) with wireless

    hey there, thank you for the reply... with regards to the hot water/heating... this house is similar to my last house, where basically there is only 2 pipes form the boiler (in the garage) to and from... You are right, this will basically turn off the heating AND hot water.. all or...
  18. T

    RSJ vs concrete lintel - 8foot span

    as you can see from the pictures, the load above this opening would be static (apart from the very left of it where the landing is), the majority of the opening will be underneath the roof space, and only the centre part is actually load bearing under the i-beam/wooden joist.
  19. T

    RSJ vs concrete lintel - 8foot span

    Good morning all... I would like to remove the wall between the kitchen and the dining room. The house is a semi detached chalet bungalow. it appears that many of the neighbours have done this in differing ways, but my plan is to have a pillar either side of the opening where the support will...