Search results

  1. B

    Plug socket circuit question

    Sorry, I got confused drawing it initially and wasn’t sure about all the terminology either. What I really mean is the above quote - a double socket spurred off another double socket.
  2. B

    Plug socket circuit question

    Sorry all, feel like I’m wasting your time as I didn’t understand how double sockets were wired… The corrected wiring diagram I am proposing is below. The 4 plus on the left are two doubles. So I am only spurring one double of the other.
  3. B

    Plug socket circuit question

    The 4 plugs on the left are in a single unit, ie 2 x doubles. It is a Delta S1988 unit with 2 x 2 Gang 13A Switched Sockets
  4. B

    Plug socket circuit question

    EDIT - wrong drawing
  5. B

    Plug socket circuit question

    It’s on 2.5mm cable and on a 32A ring circuit. Technically, 1 & 2 and 3 & 4 are double sockets if that makes a difference? So mains goes into 1 which is a double and continues to 5, while also running a spur to another double (3 & 4). Earth emitted for simplicity, but wiring follows the same logic.
  6. B

    Plug socket circuit question

    I just wanted to confirm if the wiring for plug sockets below is fine (pretty sure it is). 1. I understand cleanest way would be to wire 6 plugs in a row: 1 to 2 to 3 to 4 to 5 to 6 2. Due to insufficient cable length the above isn’t possible, so considering this alternative circuit: 1 to 2 & 4...
  7. B

    Pyronix Pet Sensors & V10 question

    Camera... neighbours...
  8. B

    Pyronix Pet Sensors & V10 question

    I have a Pyronix with 2 DTP and 2 DP seasons installed which is working well. Currently, I have the pet masks removed but am about to get a small cat. I found that with the pet masks installed, the sensors were not nearly sensitive enough. Are the masks required for small cats or will this work...
  9. B

    Pyronix self install

    I have finished installing my Pyronix Enforcer and everything seems to be working fine. Took me about 5 hours, but it was my first alarm install. 2 of those were wasted on figuring out why the PIRs wouldn't go off. Turns out the pet versions have a mesh insert, which needs to be taken out (or...
  10. B

    Pyronix self install

    Thanks for the reply. So it sounds like I will be going for the V.10 kit, take out the WIFI and add a GSM kit. I'm fitting the PIRs in lounge, hallway and bedrooms. Sometimes I leave some of the bedroom windows slightly open, so the curtains might move slightly. Would DTs help with that? I...
  11. B

    Pyronix self install

    I am looking to put a Pyronix system in my house. I am planning a pretty simple set up with 4 PIRs and 1 door contact. When away, all should be active, at night all but 1 PIR will be active. I am not keen on the new WIFI/cloud systems which seem to cost £36+ per year. I want a simple...
Back