Search results

  1. M

    setting radiator flow with weather comp

    as i have pre-settable rad valves im trying to figure out what temps i should be setting them for and what return temps etc take a 500x1600 t22 what temp should i using as flow and return? should it be the max temp the boiler will use at -3? id likely be using 36.2 based on my current curve...
  2. M

    viessmann room influence devices

    so i have a 200-w combi and its great but especially on a night it heats the house more than it needs even with a low setback obviously the outside is likely far colder so it still trys to heat but the house hasnt lost anywhere near enough so even trying to do 14c setback it just slows the...
  3. M

    viessmann setting min and max pump rates

    so i have a 30kw vitodens 200w b2kf i am trying to figure out how i should have the pump configured for the min and max pump rates its currently set to 40%/60% the bits from the instructions are here im running really low flow temps and therefore dont need huge amounts of flow. the system has...
  4. M

    viessmann cant change gas correction factor

    hi, thought id have another go but i cant change the gas correction factor on the boiler in either the user setting or the installer menu's it just stays at 1.0000 no matter what i type i mean its not an issue except i want to use the data for working some stuff out regarding degree days so id...
  5. M

    lowering DHW cost on a combi (Also known as eco shower heads)

    so im my continuing quest of dicking around to get my gas costs as low as possible (for fun more than anything) i started looking at DHW production with my Viessmann 200 30kw combi it was already alot lower than with my old vaillant in 2020 my average dhw usage about 250KWH 2021 about 180kwh (i...
  6. M

    thermostatic shower not working as expected

    Hi, i have a situation where my shower(boiler) isn't working as expected The shower is a flova go click valve (few years old but on whole house softner) and boiler is a viessmann 200 combi (brand new) Im trying to run the DHW at 38c as it doesn't need to be any hotter (please no legionella...
  7. M

    Viessmann vitodens 200 low modulation low run time high return temp

    Hi brand new install of a 30kw 200 combi And it isn't doing what I'd expect or hoped It's set with a 50c Max temp range rated to 23% heatloss is less than 7kwh But it is having very short burn runs of about 5-7 minutes And I'm only getting about a 10c drop between flow and return yet I...
  8. M

    Help with Vaillant ecotec plus 937

    Hi I have a Vaillant ecotec plus 937 its a gen 1 version as far as im aware so doesnt have the menu on the display like the later version. Anyway it was installed in a new build 6 years ago 4 bed detached with 2 adults. last year i installed evohome (with opentherm) using ATP921R3100...