  1. P

    Pumping over problem

    If youre having pump back then the expansion pipe is fitted after the pump and not before, also the motorised valve could be closed, i suspect a wiring problem that the motorised valve has not been wired to switch the boiler and pump off, another prblem could be is it an old house? if it is then...
  2. P

    Hot water is way too hot (Gloworm Spacesaver boiler)

    i would imagine that the sytem doesnt have a tank stat and should have one, The desired water temprature should be 65Deg. how old is the boiler??? i would suspect a stst on the boiler somewhere
  3. P

    Repeated fault with mid position valves

    you will need the 5 wire wiring diagram and a tester to rewire it correctly, the motorised valve should switch the boiler and the pump on.
  4. P

    Leaky lockshield valve

    The lockshiels valves that leak are the cheap and cheerfull ones, You can buy better ones that have o rings on the shaft that last for years, Tighten the gland nut and put a dummy cap on there to stop people tampering, do not rotate the shaft just incase the system has been balanced properly.
  5. P

    pressure up on boiler

    your filling loop should be disconnected after topping up the system, if the non return valve fails on your loop and it is connected and turned on it could backflow and contaminate and perhaps cause legionaires disease to the locall people, to release pressure find the bow off valve and turn...
  6. P

    Combi boiler not firing up. Its freezing!

    Combi boilers do not operate if system pressure is below.6bar find your filling loop and top up the system.
  7. P

    Power Shower and Condensing Boiler

    Power shower will not work with a combi, You will have to fit a mixer valve and bring the hot and cold in 22mm pipe as close as you can to the mixer to ensure adequate flow
  8. P

    Problems with Ariston combi

    How much wate rpressure have you? combis dont ignite below .6bar water pressure (system)
  9. P

    SPIROVENT

    Any water vented to the atmosphere will continue to take in oxygen, alwways use fernox inhibitor no matter what the installation.
  10. P

    Expansion tank - Looks like I've got a problem. Please Help

    The expansion pipe has been fitted at the wrong side of the pump, check that the expansion pipe thats blowing over is behind the pump not in front of it.
  11. P

    Rushing Sound

    Fit an automatic bypass in teh airing cupboard, about 15 quid from www.bes.co.uk or rremove all the thermostatics from the downstairs and fit a wireless room stat.
  12. P

    Filling A Vented System?

    Find a draincock on the system, fit a hose pipe, insert a wine cork into the expansion pipe at the tank and turn on the main water, it should reverse the blockage for you, other than thet you will have to cut the joint where the cold feed enters the system. Are your rads in teh loft? have you...
  13. P

    Water Hammer Arrester

    water hammer arresters are only like little expansion vessels, they need to be fitted within 2 metres of the problem, i am sorry mate but you will have to get up into that attic and secure that coper pipe from bouncing around when the ball valve is bouncing.
  14. P

    waste hole not lining up with new toilet bowl

    when you buy close coupled toilets, you can buy ones which have a horizontal exit on the rear of the pan which range from 4 to 6 inches from the wall, do your homework before you buy, also the centre of the soil pipe should be 6 + 1/2 inches from the ground. good luck
  15. P

    L reg Escort Diesel - Heater problems

    what is the position of the temprature needle when driving? are you sure theres enough water in the header tank?
  16. P

    Cracked tiling around shower control

    please post some pics and i will help
  17. P

    Pilot will not re-light. Gas valve problem??

    i dont think its the thermocouple, i would say that the primary jet in the pilot is fouled with dust etc, a simple boiler service will sort it out, You should leave the boiler for 10min before trying to relight,
  18. P

    Help very bizzare problem

    does the pilot light at all? and will it stay lit?
  19. P

    Boiler / heating problem

    Has the system two motorised valves? it sounds to me that they have wired the valves the wrong way, meaning that they have given priority to hot water, is there a tank thermostat fitted?
  20. P

    Worcester heat slave pressure problem

    remove the copper pipe from teh expansion vessel and stick your little finder in the vessel (nothing else) and the rubber diaphragm should be pressurised and taught, if you cannot feel the diaphragm then it has perished, remove the valve cap, it looks like a car valve and connect a foot pump...