  1. T

    diy alarm

    can anyone recomend a diy wired alarm cheers :D
  2. T

    Moving house and needs windows - UPVC white, grain or h/wood

    white upvc , beware of brown upvc as they can absorb the heat and sometimes warp
  3. T

    second soil pipe

    anyone know about minimum depth of plastic drains i found some imformation which states the minimum depth for plastic pipe in gardens is 600mm , the deapest any pipe in my inspection chamber is 340mm and if i lay the new drain at the other end it will be only 165mm which seems very shallow...
  4. T

    second soil pipe

    masona, thanks for your help i think thats sorted everything out i just need to find out about wether or not i need some kind of permission to do this the inspection chamber is in my garden so maybe i will ok cheers dave
  5. T

    second soil pipe

    not sure how to work out the fall rate 1:40 does that mean for every metre the fall is four centimetres . the depth of the pipe exiting the inspection chamber is 340mm and the length of pipe needs to be 7 metres long which would mean at the soil pipe end it would be only 60mm below the ground...
  6. T

    second soil pipe

    i have had the lid off the inspection chamber and the existing soil pipe exits the chamber has a slight bend in it then a straight run to the soil stack the length of pipe is approx two metres, the only way i think i can do this is to fit a y piece into the existing underground pipe and then it...
  7. T

    second soil pipe

    what is a swept? i have had a look at the man hole and yes i can go directly to the man hole, i see what you mean about getting a tee on the original pipe ,also are there regulations on how much fall should be on the pipe and is it ok to lay the pipe directly on to the soil or do i have to put...
  8. T

    second soil pipe

    the existing soil pipe is on the same wall , what i am trying to do is have a second soil pipe appox 12 feet further along the wall from the first but would like to connect it to the pipe underground that runs from the first one by adding a tee junction
  9. T

    second soil pipe

    anyone ?
  10. T

    second soil pipe

    what i mean is i cannot connect in to the existing soil pipe i will have to have a new soil pipe approx 12feet along from the first one run it down the wall and then underground and connect with a tee junction into the existing one
  11. T

    second soil pipe

    i am installing a second bathroom for which i will need to add a second soil pipe appox 12 feet along from the first one, is it just a case of adding a tee junction and extending the existing underground pipe along and then up to the new bathroom. also is it best to work from the bathroom end...
  12. T

    combi boiler

    i need to replace my old boiler which is a standard gravity one with hot water cylinder, i am thinking of replacing it with a combi boiler, the one i am thinking of using is a baxi combi 105e ,anyone know if this is a good boiler or can you recomend one. cheers