  1. B

    Nest Thermostat

    After checking again bob1956 said: should read 2 on cylinder stat -orange on zone valve & linked to L on boiler My bad. Just to add the HW is not permanently calling for heat , it just comes on randomly at different times to how I have scheduled it . The orange wire is not permanently live.
  2. B

    Nest Thermostat

    Thanks guys for your input , Ill double check later at the orange wire, are you saying if the orange wire in connected to a permanent live that is why my HW is coming on randomly ?
  3. B

    Nest Thermostat

    I have the nest 3rd gen; stat, running with a heat only boiler (Vaillant) on a Y plan system. Cylinder stat -Honeywell L641A1039 3 way motorised valve Danfoss HSA3. The problem I have is with the HW scheduling, I have scheduled HW twice a day 1 hr each time, ie; 0700/0800 & 1700-1800 However...
  4. B

    Danfoss Randell Type HSA3

    I didn't say there are 2 wires connected to the same terminal
  5. B

    Danfoss Randell Type HSA3

    Thanks for the replies, Just to add I am using a nest thermostat Gen 3 Danfoss 3 way valve is connected thus Orange -#1 cylinder stat.Blue- Neutral. Grey #2 cylinder stat. Brown/White -#3 heat link (heating on) I have the Heating stat wire unconnected at this time
  6. B

    Danfoss Randell Type HSA3

    hi I just replaced mu 3 port valve with the above valve, Wires are Blue,Orange,Grey, Brown/white,(4 wires), (I have no wiring diagram) When calling for heating, I get hot water,clearly I have 2 wires connected incorrectly . My question is, Which wires have I got wrong.:eek: Thanks
  7. B

    Vaillant Ecotech Plus 24 kw

    The hot water on the above boiler is running cold showing S53,only one fault code showing F22,I suspect that's historic. I have just changed the programmer because the original fault was no heating,which fixed that problem. However the customer asked me to check the HW supply it was then I...
  8. B

    Vaillant 424 open vent ,pump over run.

    Thanks Agile can you clarify which wire goes where(see attachment) as I dont want to damage the board
  9. B

    Vaillant 424 open vent ,pump over run.

    Ok Iv run the cable in as you pointed out ,my head is fried now just to clarify the orange wire connects to 240v or the RT, on the boiler And thanks for your help
  10. B

    Vaillant 424 open vent ,pump over run.

    Yes sorry you are correct,my bad I have connected as you rightly say
  11. B

    Vaillant 424 open vent ,pump over run.

    The nest has been wirered as per MI LN, link from L to 2 & 5 on heat link 3 to heating on 4 to HW on 6 to HW off Heat Link fitted 1 mtr from Stat.
  12. B

    Vaillant 424 open vent ,pump over run.

    No the pump is connected to x14 on the board. Should the pump be connected as per diagram
  13. B

    Vaillant 424 open vent ,pump over run.

    Is this the connection you mean
  14. B

    Vaillant 424 open vent ,pump over run.

    Ok, hot water timed for 17hr this evening,boiler didn't fire nest room stat set at 30deg,to force boiler to fire,boiler didn't fire ,S30 indicated (no call for heat ,) This is with the 24v link removed, Pump connected directly to X14 on boiler. Am I missing something hear
  15. B

    Vaillant 424 open vent ,pump over run.

    Yes I think you are right ,I was too impatient,at the time I was having problems with the nest ,im on my 3rd nest and this one works yeh
  16. B

    Vaillant 424 open vent ,pump over run.

    I previously removed the link,with what I thought no change,I must have been too impatient doh, I have removed the link now all seems ok Thanks both for your input
  17. B

    Vaillant 424 open vent ,pump over run.

    240v I have not removed the 24v link on the board