Search results

  1. Ab12

    Kinetico 2020c HF softener help!

    Having had to softener installed for a number of years and then having it sit in the garage for a while before re-plumbing my new home. I started to have issues where the water would be soft for a maximum of four days before turning hard and requiring a few manual regens to get it up and going...
  2. Ab12

    Overhang on two sides of flat roof

    As I understand, you have an overhang on one edge of a flat roof to take the fall and hold the guttering. So then two side edges of the roof have the upstands and you can see the gentle slope. What can I do if I want two sides of the roof to overhang? Say for example the front and one side...
  3. Ab12

    Double Garage Lintel Spec

    What size padstone?
  4. Ab12

    Double garage lintel double check

    Dimensions above. Ideally also I'd like to have roof joists running front to back across that 5.8m span but I can have them across the 5.25m span (though it would change plans in the visible garden - which is the side of the garage); flat roof, EPDM. May do insulation inside at later date, no...
  5. Ab12

    Double garage lintel double check

    Will get the proper dimensions shortly, and very much appreciated!
  6. Ab12

    Double garage lintel double check

    What is BRA? I have an opportunity to swap it out for 203 x 203 x 46. Would that be more appropriate?
  7. Ab12

    Double garage lintel double check

    No BCO. It's a double garage, just under 30m²
  8. Ab12

    Double garage lintel double check

    Yes via the phone in a verbal discussion "I think UB will be okay, a 233*133, let me double check but should be good"; and was meant to return to me with calcs and document, 3 weeks ago. Now radio silence
  9. Ab12

    Double garage lintel double check

    He hasn't replied to me for over a week and I can't get in contact with him
  10. Ab12

    Double garage lintel double check

    I've a 203x133UB25 beam ready to be installed across a double garage opening, it will have a wall plate fitted and hold one end of the timbers of a flat roof, may also hold the double garage door later 2 questions 1. Is it undersized? Ive been doing some reading and seen people are using 203 x...
  11. Ab12

    Garage roof

    Out of interest, when you fit at steel height and the steel is the finished front of your building, how do you then fit fascias to this steel at the front and finish the front?
  12. Ab12

    Garage roof

    It's 6m wide 5.1m deep. So the fall will be across the 5.1m back to front (into gutter above double garage door and then into drainage leading to soakaway) I think I'll go with the wall plate option, with the wall plate tied down and some twist ties for good measure, and then bolted into the...
  13. Ab12

    Garage roof

    They are not, but out of interest when drilled are you just sitting the rafter on top of steel and then fixing through steel into wood with screws?
  14. Ab12

    Garage roof

    If directly to top of wall I get I can use the twist straps, but if directly ontop of steel, how are these secured? Thanks
  15. Ab12

    Garage roof

    Just finished the single skin blockwork for my double garage and moving onto the roof next The double door opening has a steel in position, the top of which finishes at the same level as the rest of the walls (side and back) I now need to move onto building the flat roof structure and am...
  16. Ab12

    Mains water to house drop in pressure

    Yes garden tap has a double check valve I believe!
  17. Ab12

    Mains water to house drop in pressure

    Diagram attached. The bypass seems to be okay (though may not be internally) I have now got two garden taps (one soft and one hard as in drawing) I attached the gauge to the hard garden tap which tees off immediately after the mains comes in, and then started turning on taps in the house, the...
  18. Ab12

    Mains water to house drop in pressure

    Will take a look, it's this style bypass
  19. Ab12

    Mains water to house drop in pressure

    Setup is as so: MDPE in 25mm to mains stopcock That splits immediately to an isolator then runs to softener which runs to my bathrooms up and down, toilets, kitchen sink for hot, dishwasher, washing machine etc. (the softener is currently bypassed so not active- it is a HF softener however...
  20. Ab12

    Mains water to house drop in pressure

    Needle moved when turning on the garden tap but didn't move when any other taps went on. I have a 25mm mdpe supply pipe
Back