  1. R

    Fitting a Carcass for Larder Unit

    I'm anticipating installing new kitchen units in the foreseeable future. Some years ago I fitted the kitchen in the property where I currently live and I encountered a problem which I want to learn from for this occasion. The 600mm larder unit arrived ready to fit only requiring the plastic legs...
  2. R

    Shower Riser Rail

    The valve is quite an old Aqualisa but I have no evidence to indicate that the hose and riser are original Aqualisa parts.
  3. R

    Shower Riser Rail

    I never expected that replacing an old shower riser could be challenging. Having purchased a new one and fitted it I discovered that the diameter of my hose is too wide to fit into the sliding holder. My hose has an outside diameter of 20mm and inside of about 12 or 13mm. I dont want to change...
  4. R

    Decommissioning a combi boiler - removing the flue?

    By no means an idiot question. So given that you have timber framed construction the Building Regs compliance will have been dependent on providion of adequate fire resistance of the linings protecting the external timber frame from a fire within your property. Any penetrations through those...
  5. R

    Insulation around internal soil pipe

    I've never known a soil stack be insulated on thermal considerations. In the past I've occasionally specified preformed pipe insulation around soil stacks in high rise blocks to reduce the noise of the water barreling down a plastic stack
  6. R

    Decommissioning a combi boiler - removing the flue?

    It may be the neatest solution if you are able to cut the flue internally flush with the wall and fit a plate over the hole. It would need to be fire resisting, probably 60 minutes, so something like Supalux or Gyproc Fireline board. Either way you'll need to let your landlord know what you're...
  7. R

    Magnaclean not magnetic

    Yeah the more I think about it the more I'm of the view that it must never have been magnetic from manufacture and given that it's been inaccessibly fitted for 10+ years it'll be interesting to see what the new one removes which is super magnetic. I've managed to get the boiler firing up now so...
  8. R

    Magnaclean not magnetic

    The latest on this is that I purchased a new magnaclean pro 1 as a direct swap for the defective no longer magnetic one. Having fitted it, bled it and topped the pressure up to 1.5 bar the boiler is unsurpringly showing low pressure error code but rotating anticlockwise and holding the dial on...
  9. R

    Magnaclean not magnetic

    I had reason to remove my kitchen worktops and a couple of base units this weekend and since it provided easy access to the otherwise difficult to reach magnaclean pro I decided to remove it and give it a good clean. I was surprised to find no sludge at all but when I tested the magnetism with...