  1. C

    Terraced house, water pouring down both apex walls

    Had the experts out yesterday and they said most likely the cracks in the Parapet wall but it's possible the soakers are not wide enough. So I'm just waiting for a quote. They said they fix OSB3 to the wall and then torch on 2 layers of felt. These guys look really good unlike the ones we had...
  2. C

    Terraced house, water pouring down both apex walls

    Thank you, that makes sense about the soil overloading the soakers. Much appreciated. There is also this big crack down the Parapet wall, could this cause lots of water to pour down the surface inside? I guess if water gets in it has to go somewhere. Thank you, comments appreciated
  3. C

    Terraced house, water pouring down both apex walls

    Thanks you, I've been up there today and had a close look, it all looks really good I can't understand where the water is coming from
  4. C

    Terraced house, water pouring down both apex walls

    Hi Matty, the top of the chimney is really good and there is no water or damp below the chimney. It's all down the sides so I'm thinking it's the Parapet walls or the soakers. Thanks for replying
  5. C

    Terraced house, water pouring down both apex walls

    Hi Guys, I have a terraced house with a fire wall at each end going up through the roof. Inside the roof space I have water pouring down one wall from about half way down the roof and another wall is very similar. One wall I had the soakers refitted and the Parapet covered with felt 2 years ago...
  6. C

    Consumer unit EICR c3 fail?

    Where did you get the £60 from ? The Rcbos cost £240 the Labour to fit them £150 ! That's £390 at their cheapest option OR A new £160 fuse box and Collection from the whole saler and fitting £700 so £860!!! I'm fantastic, I charge £400 a month for large 1 bed self contained flats. My work...
  7. C

    Consumer unit EICR c3 fail?

    Thanks Guys, I was not given the paperwork for the two flats that failed just the one for one that passed. The guy said c3 but since I rang them they say its a c2 and must be done. I wanted them to move the 63 amp rcd to the left to cover all circuits to save a few hundred quid but they said it...
  8. C

    Consumer unit EICR c3 fail?

    Hi Guys, I have a consumer unit regulation question I'd like help on please... So this is for a 1 bedroom self contained rental property and not a HMO in England. See picture.... So half of the circuits are covered by a RCBO and the wash machine, cooker and hot water tank are not. A spark has...