    Samsung RS21NABB (non water dispensing) left hand side deodorizer frozen over. Photos attached.

    Hi, Does anyone know what I need to do with this? I know there are modification kits but not sure yet if I need one. Any advice would be most helpful. Cheers S
  2. G

    Samsung RS21NABB (non water dispensing) left hand side deodorizer frozen over. Photos attached.

    Hi there, THIS IS AN RS21NABB Fridge. I have a samsung american style fridge (non water dispensing one) and the was cleaning it out yesterday. I noticed that the left hand side deodorizer was frozen over. Right hand side was fine. Any research i can find on the internet talks about a bunged...
  3. G

    Hi Kirk could you send me that power point to [email protected]. Thansk man

    Hi Kirk could you send me that power point to [email protected]. Thansk man
  4. G

    Gravity fed WM from a Rainwater Harvesting System

    Thanks for your reply. Its all down to cost as usual and adding in a pump wouldnt make our unit cost effective. Says i not knowing how much a pump would be? G
  5. G

    Gravity fed WM from a Rainwater Harvesting System

    Hi Folks, I fix gas boilers in the evening but during the day i design Rainwater harvesting systems. My query is about running a washing machine from a header tank. Check through some threads and the general thinking is it is okay. Was more so wondering about doing this in a Bungalow...
  6. G

    Grant Minor 50/90 S Nozzle size

    outinthestix, Completely understand where you are coming from and i know you guys have to set things up exactly to get optimum performance. Was just basically wondering if this nozzle was within the ball park as the custard is blaming his wildly increased fuel use on having the wrong...
  7. G

    Grant Minor 50/90 S Nozzle size

    Yeah i mean using more oil. Fully take on board what your saying about the winter too!!!!! With regard to the nozzle and just for my own info what size should be in the burner for this scenario?? Thanks G
  8. G

    Grant Minor 50/90 S Nozzle size

    Guy in work has noticed that his boiler is starting to chew oil. It is a 1992 Grant Minor. Reckons it has only started doing it since he changed the nozzle himself about a year ago. ] He fitted a 0.55 80 H nozzle and asked me is this the right size nozzle for this burner. Burner isnt a...
  9. G

    Vokear Mynute fires for 2 secs then out

    Went to this one today after spending all day sorting frozen condensate pipes!! Go this one and condensate pipe was frozen so sorted that. When i opened the boiler there was a load of water lying in it. Pulled off pipe to combustion chamber to make sure it wasnt full of water but nothing...
  10. G

    Sterling 40 ST 108 with inetrmittent lockout

    Corgi in N.Ireland wee lad. Yet again contribution zero. G
  11. G

    Sterling 40 ST 108 with inetrmittent lockout

    Paffman, I dont know if you are aware but CORGI people fix GAS boilers. Hence i dont fix OIL boilers. You have contributed nothing to this thread. Well done. G
  12. G

    Vokera Linea 24 - losing pressure only when heating off

    Hi matt, Had a problem with a Vokera doing this last week. Leak sealer sorted my issue though. Not sure if your Vokera had a latent heat collector in it but these can fail. The water will run done through the condensate trap and down another pipe to outside. You woudlnt see any...
  13. G

    Vokera Linea No Hot water

    DP ill re post in CC
  14. G

    Vokera Linea No Hot water

    Tony is that the wee valve you can see at the back of the DV assembly when you remove everything. It seems to be a bit crudded up but i didnt want to poke at it too much as i wasnt sure what it did!! How does one get that out? Should i just remove the HE and clean as it says its only two...
  15. G

    Vokera Linea No Hot water

    DP, Cheers for the feedback. Think i ahev already tried most of what you said though. Have pushed and held the spindle in while running HW but no joy. I then stripped/cleaned and lubed the DV assembly. Got some HW and then cold a while and contunined doing this. Flow pipe was getting hot...
  16. G

    Vokera Linea No Hot water

    Hi Tony, I tried that tonight but it was no good and didnt make any difference. Think i said in my original post that i was getting 230 V to the pins. When i took the motor out of the box the pin was in and when i plugged it in it powered forward slightly to what i assume is the CH...
  17. G

    Vokera Linea No Hot water

    Disaster, Fitted motor actuator, Ran the HW and nothing really doing. Tiny bit of HW but Ch pipes getting hot. So i pulled the DV assembly aparta nd cleaned it as best i could and siliconed the pin etc. Now get HW for about 10 secs then goes cold and cycles this way with boiler cycling...
  18. G

    Vokera Linea No Hot water

    Fair enough. Well the motor will be here in the morning so ill let you know how i get on!!! S
  19. G

    Vokera Linea No Hot water

    Hi Tony, Yeah when you run the HW tap the boiler kicks in and runs away merrily but i pulled the motor off to see if any movement and nothing. If you run the tap like this then the rads start to heat up. Am i making a serious assumption that with the motor off the DV when i turn on the...
  20. G

    Vokera Linea No Hot water

    Yeah i read in the book that the pin is a mechanical device that is pushed in by the motor so im assuming the pin needs to move!!!!! S