Search results

  1. R

    problem with a screed floor

    ive layed a screed floor in my bathroom at a depth of 25 mm as per building plans , its bean layed for a month and is cracking badly and i have some doubts if it is sticking to concrete below , concrete is 5 inches thick and was layed 3 months ago . i did not use any sealer on concrete on...
  2. R

    one light controlled from 3 swiches - possible ??????

    is it possible to control one light from 3 light switches ???
  3. R

    hot water tank

    im looking to replace my hot water tank and relocate it , at the moment i have a 65 litre tank in bedroom approx 25 meters from nearest tap i want to move it to bathroom and reduce it size as im removing bath and fitting a large shower cubicle with electric shower . idealy im looking for a tank...
  4. R

    Do you need to pass a medical examination when training.....

    i did my apprenticeship with blue circle and i had to have a basic medical and colour blindness test
  5. R

    A few pictures of my fuse board!!

    i put a mk board up last weekend and i cant fault it , plenty of room and well laid out
  6. R

    A few pictures of my fuse board!!

    whats the cable for on the right hand side with the terminal block
  7. R

    Boiler damaged by meter installers error!

    supply across two phases should be 415v not 315v , did you measure 315v ???
  8. R

    Night Storage Heaters vs Electric Wet Central Heating

    where i live there is no mains gas available and i did not have a site for an oil tank . there are a lot off people in the nearby village that have converted from bulk gas to electric wet heating . my dad's electric bill is about £ 45 a month for his total electricity consumption
  9. R

    Night Storage Heaters vs Electric Wet Central Heating

    what type off heating do you have at the moment ?? do you have radiators in place ??
  10. R

    Night Storage Heaters vs Electric Wet Central Heating

    water comes direct from boiler when its called for , sytem is controlled by danfoss tp5000 +rf fully adjustable times and temperture in each time zone . with the rate i have it's off peak 18 hours off the day . i needed to change consumer unit to handle two incoming meter tails , i also feed...
  11. R

    Night Storage Heaters vs Electric Wet Central Heating

    only had meter fitted for two weeks and with this weather ive not had heating on . my hot water comes from the immersion but im going to change that so boiler runs through immersion tank before heading to radiators . ive got a trianco aztec 12 kw system which heats my 3 bedroom semi ( 200 year...
  12. R

    wylex fuse box/ cover

    is the cover tight on mcb's ?? do they have room to operate ???
  13. R

    Night Storage Heaters vs Electric Wet Central Heating

    ive got electric wet heating , im on scottish power 2000 economy rate . cheap rate 02.00-08.00,10.00-16.30,18.30-2400.
  14. R

    mk circuit breakers

    they used 16mm t+ e cable
  15. R

    mk circuit breakers

    im using a hager 63A mcb at the moment thats what the installation engineers fitted into my old clipsal board .
  16. R

    mk circuit breakers

    i know the current but mk dont make any thing above 50A and thats a bit close to running current for my liking
  17. R

    mk circuit breakers

    12kw electric heating boiler
  18. R

    mk circuit breakers

    ive fitted my new consumer unit , mk sentry split load board . i require a 63 A mcb for heating supply , mk site only shows them up to 50 A . does anybody know of another brand which is compatable with this board ???
  19. R

    Pulling the main fuse

    my main fuse has no seal on it , scottish power removed it and they have bean back 4 times and nobody has resealed it.
  20. R

    Location of Consumer Unit.

    i had a some dodgy electrics when i moved in to my house . 1/ shower pull swich situated above shower unit over bath . 2/ fire place wall socket had bean moved out from wall , one of the brick wall tv unit thingies , cable from left hand double socket went to ceiling rose bolted to socket back...
Back
Top