  1. K

    Gas Fitters Only Forum, The Combustion Chamber

    Hi I am RGI in Southern Ireland, can I apply?
  2. K

    Baxi Solo 3 Pilot solenoid

    Spot on gas4you, it was the APS. Many thanks to you, Namesag and Nicknox for your valuable replies.
  3. K

    Baxi Solo 3 Pilot solenoid

    Thanks for the suggestions guys, will let you know the outcome.
  4. K

    Baxi Solo 3 Pilot solenoid

    Thanks I will check tomorrow. Does anyone know the answer to my original question regarding the pilot solenoid resistance and the effect this may have on the supply to the fan.
  5. K

    Baxi Solo 3 Pilot solenoid

    Hi all, I got called out yesterday to Baxi Solo 3 50 PF. Water circuit and pump fine. Boiler works first time from cold but wont restart 1 minute later if switched off. If it is left running it will heat rads as per normal till preset temp is realised and wont fire up again for approx 6 hours...
  6. K

    Vokera mynute 14 SE

    I have the following problem with a vokera 14 mynute se boiler. I have sparking at eletrode but no ignition. Gas valve solenoid was buzzing so I replaced gas valve with no success. I then replaced the ignition pcb but still no ignition. Looking at the manual points me towards the high limit...
  7. K

    Baxi Solo flue connections

    The flue incoporates a 300mm horizontal run before elbowing vertically so gravity does not prevail. the boiler is standard efficiency (condensing still not compulsary in Ireland). The overlap of mating parts at the elbow is only about 15mm so I have decided not to trust a frictional grip. My...
  8. K

    Baxi Solo flue connections

    I am having problems with the rubber sleeve and clamp connections which connect the elbows and flue extensions in the vertical flue installation I am installing to a baxi solo (also applies to baxi systems boilers). They don't offer much grip when fully tightened and pull apart very easily...
  9. K

    Glow-worm Micron versus Ideal Classic

    Condensing is not yet compulsary in Ireland.
  10. K

    Micron 50FF Problems

    The thermistors range is 2.5k ohms to 14k ohms for testing . The new thermistor was just below 14k ohms.
  11. K

    Micron 50FF Problems

    No need to suck eggs, polarity correct, pcb correct. Thermistor resistance reading outside of ohms range. New thermistor fitted and everything working fine. Many thanks to Corgigazza and the other guys who gave constructive advice.
  12. K

    Micron 50FF Problems

    Just fitted a pcb to a glow worm micron 50FF due to the following: Fan only starts up when spur fuse is switched off and then switched back on again. This happens even though the boiler control stat is switched off and then everything stops without firing. The led sequence points towards the...
  13. K

    Vokera mynute 16e

    Thanks guys for your advice.
  14. K

    Vokera mynute 16e

    The following problem exists with a Vokera 16e: It wont fire at start up, pump runs, fan runs. When I remove the combustion cover it fires, runs for approx 5-10 seconds and stops firing. It repeats this process continuously while the fan continuously runs. APS tubes are fine and tight...
  15. K

    Ravenheat CSI Primary Condensing boiler

    The APS tube that is free is about 4 inches long and just juts out straight ahead. Flue seals are fine and APS appears to switch on and off fine. I will check the continuity between elecrode tip and pcb before I purchase a new pcb (providing I can get one over here for this model GC 47 581...
  16. K

    Ravenheat CSI Primary Condensing boiler

    Its 4 years old. The installer was the Irish equivalent of CORGI, Bord Gais approved. One of the APS tubes does not connect to anything at one end. Is this the norm for this model.
  17. K

    Ravenheat CSI Primary Condensing boiler

    I have a problem with a Ravenheat primary condensing boiler that fires and stops repeatedly every 5 seconds or so. Has anyone encountered this problem before.
  18. K

    Baxi Solo 3 fires and stops repeatedly

    Right on the button Poxy. Very slight crack on APS tube and everybody's happy. Thanks guys [/img]
  19. K

    Baxi Solo 3 fires and stops repeatedly

    Thanks for the suggestions guys. Will follow up and report how I get on. It will be about a week as I'm off on holiday. Fishing must be good at the moment as a friend of mine who never catches anything caught 2 sea trout at Ballymoney Wexford last week . :wink: [/img]