Search results

  1. F

    Smeg SUK91MFX7 - main fan oven not working

    Hi all, I've got an issue with our Smeg SUK91MFX7 90cm cooker. The main oven function (i.e. two round elements at the rear surrounding the fans) has stopped heating. The lights and fans come on OK but just no heat. The top/bottom elements and the thermostat work OK when using the other...
  2. F

    Lapping DPM onto existing DPC

    Hi all, Quick question - I am converting my garage and my BCO has suggested that an acceptable floor would be: - * DPM lapped to DPC straight on existing concrete base * At least 70mm PIR insulation * Another DPM lapped to DPC * Moisture resistant 18mm chipboard (floating floor) This...
  3. F

    garage conversion inside wall construction

    Great post oldun, just a couple of quick questions.. What do you mean by "screw 300mm lengths of fir band"? I assume with your method that the plasterboard sits against the pier with no insulation between them - is this OK? Cheers. PS I'm the OP from the "other thread"
  4. F

    Single-skin wall insulation - thick Celotex

    Thanks, yeah, I agree - the Celotex, Kingspan and Xtratherm websites all seem to say something slightly different though - here's an extract from the Celotex PDF: - * Ensure that existing walls are permeable. Strip any gloss paint or vinyl wallpaper. * Install a breather membrane where...
  5. F

    Single-skin wall insulation - thick Celotex

    Thanks, that's interesting, I hadn't seen that thread. Thanks, looking at the Celotex website I think the idea is not to have an air gap so that air can't circulate back there (but I'm no expert!). The only problem I can think of with the shallow stud wall is that to fix the sole plate to...
  6. F

    Single-skin wall insulation - thick Celotex

    Hi all, I'm currently converting my (attached) garage. My plan for the long external wall is: - (Existing external single leaf brick wall) Breather membrane 100mm Celotex (sealed to form vapour barrier) 50mm tanalised softwood horizontal battens at top and bottom, plus vertical battens...
  7. F

    Lintel in Single-storey Garage

    OK, thanks. I'll get on with it then and get the doors installed...
  8. F

    Lintel in Single-storey Garage

    Cheers, wouldn't a double course concrete lintel have the same issue though, especially as it wouldn't have any bricks at all above it? Or is it just an issue with single-course lintels? Thanks - I'll stop stressing (no pun intended) then. I think I'll carry on and get the doors installed. My...
  9. F

    Lintel in Single-storey Garage

    I'll take some when I have a minute (and some new batteries for my camera). Somebody else mentioned to me (typical, after its done) that the lintel should really be more than 70mm high as there is only one course of bricks above. However surely the 70mm one is better than a double-height one...
  10. F

    Lintel in Single-storey Garage

    Cheers hotrod, I installed it today after propping up the joists - no problems. Thanks again.
  11. F

    Lintel in Single-storey Garage

    Hi all, I have a couple of lintel questions... I am opening up a hole in my garage wall to install French doors. The opening for the doors will be 1200mm so I am intending to install a 1500mm lintel. It's a single story attached garage so the roof is quite low - there is only one course of...
  12. Garage Rear Wall

    Garage Rear Wall

  13. Garage

    Garage

  14. F

    Replacement glass disc for cooker hood light fitting

    Sorry, I never got around to looking for a glazier so its still broken. Did you have any luck?
  15. F

    Powering External Alarm Siren from Loft

    Thanks - I've bought myself a fused switch so I guess I just need to find a 1A fuse to go in it, and then wire it into the lighting circuit up in the loft. Thanks again.
  16. F

    Powering External Alarm Siren from Loft

    Thanks, I'm not bothered about the warranty (unit is >2 years old) and to be honest, it'll probably be easier to chop the plug off to re-route the cable. So what are my options - fit a shaver socket in the loft as you suggested and then re-attach the plug? Or (and this is where I'm a...
  17. F

    Powering External Alarm Siren from Loft

    Didn't think it was important... Yeah - the instructions say that, but its not a wall wart, there's a separate transformer with a lead coming from it with a shaver plug on it... Cheers...
  18. F

    Powering External Alarm Siren from Loft

    It's a Visonic MCS-700 I want to re-route the cable as my temporary (well, was supposed to be temporary 2 years ago) installation means the wire is a bit unsightly.
  19. F

    Powering External Alarm Siren from Loft

    Hi all, I have a burglar alarm siren that is powered by the mains - it came with a shaver-type plug on the lead. At the moment its plugged into a mains socket in an upstairs room, but I would like to re-route the cable into the loft. Is it possible to power it from the lighting circuit...
  20. F

    Replacement glass disc for cooker hood light fitting

    Thanks, didn't think that a glazier would cut something so small and precise but I'll check. Also, would I need special glass if it's sitting under a halogen light? Thanks. again
Back
Top