Search results

  1. I

    Baxi condenser boiler cutting in and out

    I have a Baxi Barcelona condenser boiler (yes it's 21 years old and yes this model has issues). Mine has been largely reliable and had a new pump in 2020; it is not leaking and holds pressure and we always have hot water for taps and heating. It's currently going through phases where the...
  2. I

    Boiler cutting out - no hot water but heating OK

    I have a Baxi Barcelona condenser boiler. It was working fine, apart from leaking flow and return isolator valves after he changed the EV and PRV. My plumber changed these (not a full drain down but wait for a vacuum to be created - it's an unvented megaflo system). Then after a couple of days...
  3. I

    Boiler losing pressure

    Hi - I'm trying to diagnose why my Baxi Barcelona condenser boiler is losing pressure. It's connected to a megaflo and underfloor heating. I've turned off the flow and return on the underfloor heating and the problem is still there, so I assume that takes away any possibility of a leak within...
  4. I

    Miele G692 dishwasher not draining

    Miele G692 dishwasher not draining - the inlet/drain light comes on and I find that the area under the silver mesh filter in the base is full of water. When I bail out the excess water and reset the machine it carries on, sometimes until the end of the wash. If I disconnect the waste pipe from...
  5. I

    Raft foundations for a garage - am I doing it right?

    I'm building a garage down the side of my house. It will be a freestanding timber framed barn style single garage, with a wooden frame on a dwarf wall. It will measure 6m x 2.5m (exempt from building regs) and will have the house one side and a 6 inch gap until the neighbour's fence on the other...
  6. I

    Building a garage - need advice with foundations etc

    Hi - I'm going to build a single detached garage this year. I have a narrow strip of land between my house and the neighbour's fence. I have done my own drawings and have planning permission. It's 6m long x 2.5m, so only 15 sq m and exempt from Building Regs. I need a bit of help to make sure...
  7. I

    Who is correct - my plumber or the water softener engineer?

    Hi - I'm seeking some impartial opinion on whether a fault with my water softener has been caused by a faulty part or whether it has been caused by my plumbing system. To cut a long story short, my house is 5 years old and has a pressurised water system with a Megaflo. My incoming water...
Back