    Bristan 1rbs1cp reflection problem

    i recently fitted the tap with a new basin. It was fine, then the customer rang to say it was constantly running. I went back and yes it was. I spoke to Bristan whose technical team refused to speak to me at first. I checked the sensor and that was working well. The tap was away from reflecting...
  2. S

    Anyone fitted esi esctde

    ive been asked to fit a "intelligent"(I'm obviously not), electronic dual thermostat. Absolutely lost on the installation manual. Need to see a picture of one already put in. I'm assuming the probes go where the immersion stat goes.
  3. S

    Radiator on CH system not heating up

    Hi, A customer called saying that a rad wasn't working on their system. The system is 10mm microbore. Initial thoughts were balancing, so tried to force it to force heat into the system to no avail, rad only got luke warm at the top with what looked like the rad being classically sludged up...
  4. S

    Powermax 185 query

    Has anyone come across this boiler before? The manufacturer is IMI heating, which does not exist anymore. I have managed to get installation instructions for ia 185 but the manufacturers on both are either RSA heating or Baxi....so I'm a bit confused (as usual the customer does not have the...
  5. S

    link from dishawasher hose to bosch dishwasher keeps blowing

    I am at my wits end. My dishwasher is on an extended hose and is linked by a compression fitting ti a bosch dishwasher. It was fine for a few months, then the hose blew off the fitting! I had PTFEd the plastic fitting, as required and was shocked when this happened. So I changed the fitting...
  6. S

    shower mixer tap query

    Hi, A customer has a shower mixer tap, where the water is either roasting hot or freezing cold when the shower is used. I went to have a look at it and it is gravity fed hot and mains cold. I had a look at the installation, no isos and no check valves. When the shower is on for a period of...
  7. S

    close coupled cistern leak- help appreciated!!

    Hi, I changed a syphon on a stelrad doulton close coupled wc, changed the mounting kit and changed the foam washer. It leaked constantly from the front and back, so tightened up the syphon as much as I could replaced and it still weeped slightly. So changed the foam washer and put...
  8. S

    Galaxie 346 back boiler

    I went to service a back boiler and found the fire and the boiler were spilling, so I isolated the appliance told the customer to either get a builder to look at the flue or get some quotes for a new boiler ( told her I did not do swaps as she had not paid the bill up to date so did not want to...
  9. S

    Radiators getting hot when hot water only set on programmer

    Has anybody came across this before. On a y plan (GW ultimate 50 boiler) when the programmer is set to hot water only the radiators warm up substantially. When set to c/h only the cold warms up slightly but the radiators do warm up. I am tending to point the finger at the three port valve. Any...
  10. S

    Potterton kingfisher 45 cf manual

    Has anybody got a manual for a potterton kingfisher 45 cf? I have rung potterton and they said that it was only available on partsarena. Tried but could not find it. Thanks in advance
  11. S

    sludge, 15mm pipes, 15 rads and balancing problem

    Hi I would welcome anymore suggestions as I am about to blow my top. Got a s plan hybrid system it looks as though the only 22 mm is from the flow and return. there are 3 15mm drops each feeding at least 3 rads tothe ground floor. The problem is that the rads to the ground floor are not...
  12. S

    Service manual for Crosslee royal cozyfire super 16

    Has anybody got a copy of the crosslee royal cozyfire super 16 they could forward to me. I rang crosslee for this and they just sent me a copy of an exploded diagram!!!!! Thanks again!!
  13. S

    service manual for wall mounted potterton netaheat profile

    Has anyone got a service manual they could forwrd on to me for the potterton netaheat profile? Cheers
  14. S

    caravans!!

    I have been asked to add some radiators to a mobile home, however the pipework did not like it was done in copper (it had been sprayed silver, but the joints were just too perfect to be copper, if you know what I mean) Can anyone advise on this??
  15. S

    partL query

    when swapping boilers, under part L is it a regulation to change single panel rads to single panel convectors or just a recommendation??
  16. S

    Flavel The Regent gas fire manu instruction guide

    Has anybody got or can point me in the right direction for the manufacturers instructions for a Flavel the regent radiant gas fire, for servicing purposes as the installer did not leave these with the owner and I would like to have a quick look before I go to the job. Just had a quick look on...
  17. S

    Twin entry microbore rad not working

    A customer had a rad replaced which is twin entry microbore about 2 years ago. She says it has never worked. So checked the obvious (the valve open), found it was getting slightly warm at the top, cold at the bottom, rad tails are warm. So turned off all rads except this one, still did not...
  18. S

    thermostatic shower shut off

    My thermostatic shower keeps switching off during showering. It does not suddenly become too hot, it just simply gives up the ghost. It makes no difference whether taps are being run in the bathroom ( as I thought that it could be the ballvalve in the loft not replenishing the cylinder fast...