    Kitchen Door (entrance) - regulation

    Many thanks for the comments. I had trouble understanding the reasoning in the first place, but the old dear planted a seed of doubt which thankfully you've removed. Cheers
  2. S

    Kitchen Door (entrance) - regulation

    I have a query as to whether I can re-hang my kitchen door on the opposite side of the frame - the door used to open into a kitchen from a small hallway. To free some space up in the kitchen I now want it to open into the hallway. I was all ready to do this however my neighbour informed me...
  3. S

    Bath filler from thermo mixer - 15mm or 22mm?

    A big thank you to everyone. Well the current mixer is now redundant and a new one is on its way. the hot water is now a trickle and thankfully the supplier is sending a direct replacement - so although the first mixer seems to be at fault after trying every conceivable connecting and...
  4. S

    Bath filler from thermo mixer - 15mm or 22mm?

    Having checked there are indeed casting on the valve and thankfully I had the hot and cold the right way round and I had not fitted the restrictors to either inlet. I spoke to Saggittarius and they will be sending me replacement valve inserts (plastic gubbings which act like a single check...
  5. S

    Bath filler from thermo mixer - 15mm or 22mm?

    good point and no with regards to the ports. How do you tell whih is hot and which is cold? I worked on cold - right, hot left? bit of a pain if wrong - will contact the supplier to check which way the ports go. However, (he said) although no instruction whatsoever, there were two small...
  6. S

    Bath filler from thermo mixer - 15mm or 22mm?

    Hmmm. Connected the hot pipe and unless I practically close the cold lever valve the cold pressure seems to be preventing the hot from flowing. Not good. Any suggestions as to how I can get at least some cold and more hot as I need to have the temp on hotest and the lever valve on the cold is...
  7. S

    Bath filler from thermo mixer - 15mm or 22mm?

    I contacted the supplier/manufacturer of the mixer and they told me it didn't come with a check valve (although having said that, I had to explain what they were) - however there are small plastic fittings in each inlet which looked like valves - white nylon cup around a spherical insert. Now...
  8. S

    Bath filler from thermo mixer - 15mm or 22mm?

    I am about to connect the pipework to a new thermostatically controlled 3 way mixer - with 2 showers and 1 bath filler. The inlets for the hot and cold are both 15mm as is all the pipework in the flat - the flow rate is 18L/min for cold (mains fed) and 9L/min for the hot from the combi boiler...
  9. S

    WC not aligning with soil pipe

    Unfortunately removing the whole cast pipe is not an option. I have cut the cast iron pipe back to remove the collar and pushed the rubber grommet and flexi pipe back in and it seems to be ok (for the moment). However, I would be happier if I could get a tighter fit - I will look into fitting...
  10. S

    WC not aligning with soil pipe

    Hello again - well I've finally had the new pan etc delivered and so about to tackle cutting the castiron soil pipe. I have a new connector with a rubber seal - the question I have is as this is a wall hung pan with the cistern concealed behind some plaster board - how can I make the seal as...
  11. S

    Fitting a bath/shower thermostatic mixer

    Ok, not had the mixer delivered yet but I've spoken to the supplier and they've assured me it doesn't have one so I'll just fit them as necessary.
  12. S

    Plaster on plasterboard

    Thanks Brist, just what I was looking for.
  13. S

    Plaster on plasterboard

    I've blocked up an old doorway with a stud wall and square edged plasterboard and I'm looking at finishing it off. a) What sort of plaster do I put on to it (board finish, multifinish etc) b) Do I need to prepare the boards i.e. prime/put a base coat on (if so, what sort of plaster?) c)...
  14. S

    Fitting a bath/shower thermostatic mixer

    Having nearly finished my kitchen, in true DIY style I've started on the bathroom and although I can see and have read a lot of threads here on fitting showers, I just want to make sure I have all the bases covered. In essence - I have: 15mm pipework throughout Boiler (Veissmann Vitroden 100...
  15. S

    WC not aligning with soil pipe

    I broke my pan the other day, walked into it with a 9lb sledge hammer by mistake. So I took all the measurements and went to B&Q to pick one up (it was 7pm on a Sat night). Could I find one - no! So I bought a close fit, flexible coupler and proceeded to fit the WC. The problem is that the...
  16. S

    How musch room does a washing machine need?

    I'm installing a washing machine and dishwasher into a new kitchen, now the standpipe and cold feed are pretty straight forward, the question I have is........how much sapce is required to the left and right of the appliance? I'm fitting the kitchen into a bare room and with the worktop not...
  17. S

    Kitchen Wall Units

    Ok, I 've fitted the wall units first - well, they're on the hangers - and I have found that the corner unit is out by approx 6mm on the right hand side when flush and pushed into the corner. It is a diagonal corner unit and although there will be an open wall unit (the thing with shelves on...
  18. S

    Combined waste pipe best practice

    I have a first floor flat and I am about to embark on plumbing in the sink, washing machine and dishwashers waste pipes. There is currently no hole in the wall so having purchased a 40mm core drill bit to feed a 40mm pipe through the wall. As I am on a first floor flat do I need to fit any...
  19. S

    Self Levelling Compound - anything but

    The 6mm was in a corner measured with a 1.2m length. However, I have now found a large mound which is about 8mm higher than the surounding area (the mound has a diameter of approx. 50cm) whih in turn is 6mm higher than one corner. My plan of attack today is to chase in channels at the left...
  20. S

    Self Levelling Compound - anything but

    Morning all and happy 2007!!! Ok, I've just mixed and put down two bags of BAL Multibase to cover 10m2. The consistancy was the same as that on the wonderful DVD I received from the tile supplier. I pushed the SLC into the corners and coevered the whole area.......now I was under the...