  1. M

    Led batten light from spur

    I have an existing fused spur in an extension/utility room currently not being used, I intend to run a ceiling light from the spur and am considering this. Just running 1mm T&E from spur straight into switch keeping continuity with E and N and running live through switch then up to light... Is...
  2. M

    cooker 6mm

    9.0 KW cooker 20 meter run 10 mm cable 40 Amp breaker Is it possible to attach 6mm cable from the cooker outlet point to the cooker even though the rest of the run is 10mm ? the reason I want to run 6mm is because there is not much room at the back of the cooker and was thinking pulling...
  3. M

    cooker outlet

    Is there a minimum height off the floor for the cooker outlet point, also what length of cable is recommended from cooker to cooker outlet point. Does it matter that the cable may dangle on the floor when the cooker is pushed back to the wall?
  4. M

    cable run

    10 mm cable, shallow plaster. is at a case of hammer, chisel, bang bang. And as i pull the paper of the wall i discovered a cable run Diagonal from ceiling to a triple socket what appears to be 1mm cable.
  5. M

    spur from ring main

    Can you put a junction box into a ring main then run a spur, are you limited to only one socket on that new run? thanks
  6. M

    cooker cable

    I have used 10 mm cable throughout the run, do I use the same 10 mm cable from the outlet to the cooker? thanks
  7. M

    cooker outlet

    what is the recomended height from the floor for the cooker outlet point, and how far away from the cooker should the cooker switch be idealy
  8. M

    cable run from cooker point

    do you run the cable from the cooker switch to the cooker outlet horizontal then vertical or can you run it diagonal ? thanks.
  9. M

    fitting cooker point

    I am fitting a new cooker for someone, small single oven combined grill, i believe 1.3 kw ( INDESIT K3E1WG ). not an MCB but a fuse carrier. will it be 30 amp fuse ? will it be 6mm cable ( aprox 26 metre run ) ? and what connects the cooker outlet to the cooker? same 6 mm cable or 2.5 / 4mm...
  10. M

    Time for new boiler?

    I have a ferroli combi installed about 15 years ago at least. The boiler looses water after the central heating is switched off not before and continues to loose water as long as the radiators are warm, after system goes cold it retains its pressure, (recently it will loose some pressure...
  11. M

    incoming water

    In the front bedroom we had water coming in under the window sill, (upvc window, wooden sill) no idea of the entry point. lifted the sill and siliconed sealed it to stop water coming down wall, now the wall down stairs under the same upstairs window is becoming black with mould / damp, outside...
  12. M

    back to brick

    I got it in my head that i want to take the chimney breast back to brick, knock off all the plaster and have the original brick as the decor! Is this a good idea or should it be better left as is? If i do should i just do the breast or should i do the whole wall as well? And once the plaster...
  13. M

    Fitting cooker point

    Fitting cooker point in a kitchen with no apparent existing point. On inspection of consumer unit their appears to be a 6mm cable supported by 5 amp fuse, on pulling the fuse I only loose wall lights in the kitchen and outside lighting, on closer inspection when cover removed on kitchen wall I...