Search results

  1. K

    do you have to have a roomstat

    Big thanks to all for your speedy replies. This forum is so usefull.
  2. K

    do you have to have a roomstat

    My brother is in the process of renovating a house to live in. He has had most of the work completed, new electrics,pipework for central heating, plastering ,etc and his plumber has coming back next week to install a Worcester combi boiler. His plumber has told him that he must have a roomstat...
  3. K

    Could someone please explain

    B.A.S. by your comment ( TT opt out solution ) does that mean that if the suppliers earthing was when tested found to be inadequat that it could be disconected and a correctly installed full TT system applied.Am I right in assuming that you could not leave the TNS connected if you just added an...
  4. K

    Could someone please explain

    Thanks Nozspark and Rocky333. I understand the points you have made.I am not an electrician, but am I right to assume that if my mates C.U. installing sparks did all the checks and found that Ze for T.N.S. was within the 0.8 limit that this old small link to earth is perfectly safe and acceptable.
  5. K

    Could someone please explain

    I was in a mates garage the other day and noticed his nice new hagar consumer unit.The main earth from the earth block to the C.U. was in 16mm and the M.E.B. to the gas and water was in 10mm. OK so far but here is my querie the supply earth was T.N.S. with just a few strands, at a guess no more...
  6. K

    P.I.R./Microwave sensors

    At present I am working in a pub and along with other jobs I have been asked to look at saving energy on the lighting . My electrician intends to fit cfls inplace of halogen downlights and energy saving lamps to all other normally switched areas.The owner has requested that in areas not in...
  7. K

    additional RCD or not

    Many thanks Gary mo and Ban for your speedy replies.Ban , I know from reading your replies how accurate and serious you take the advice you give. My electrician will be installing the SY and certifying to building control, it was just realy the 2nd RCD situation, could you please explain the...
  8. K

    additional RCD or not

    I would like to take power to a garden water feature from a spur off the conservatory ring circuit which is RCD protected via a switched FCU to be installed in the conservatory, the cable run being in 2.5 SY cable to the water feature. It has been suggested that it might be better to go via an...
  9. K

    Running armoured cable around a corner

    Hi Woody I have seen instances where a 45 degree angle a little wider than the O/D of the cable has been carefully chissled across the 90 degree corner and the progressive gentle bend that you must apply to SWA has been gently teased into the created recess keeping the protrssion from the...
  10. K

    new or old footings

    Hi guys hope you can help. About three and a half years ago I had a new boundary wall built partly off old concrete footings approx 20 years old and partly off new. A neighbour is now saying this section of new wall on the old footings has been moved from the position of the previous old wall...
  11. K

    outside downlights

    Thanks for your reply Chris5 , so as long as rain cannot fall directly on to the light it is safe not to be I.P. rated.I am not bothered re the rusting, chrome outside you expect to clean once in a while it was just the safety aspect possible spray from hose pipe or condensation etc. Thanks again.
  12. K

    outside downlights

    Ive just moved into a newbuild house with canopy porch over the front door and garage. I noticed that there was some rust on the chrome bezzel of the downlights set into the plastic faced ceiling of the canopy.On starting to clean them I found they were standard 230 volt downlights and on...
  13. K

    combi boiler problem

    Thanks Chris for your speedy reply you were right the boiler is 16 years old.Just got the wife to operate the tap while I watched the boiler.When the hot tap was opened the main flame died leaving just the pilot and there was a repeated clicking noise, like a solenoid coming from the mid to...
  14. K

    combi boiler problem

    Hi guys hope you can help. I have a Celtic FF boiler,central heating works fine but the hot water from taps starts to run warm approaching hot and then runs cold within about 15 seconds.Ive tried switching to hot water only on boiler but same thing happens. Boiler is about 12 years old.Any...
  15. K

    cooker switch with socket

    thanks all ,especially Steve 3948 it appears my mate is buying the beer kind regards.
  16. K

    cooker switch with socket

    Thanks for your all your replies guys, points re nuisance tripping and it being preferable to have an isolation switch only, make good sense.But to get back to my original question is it against IEE regs at present to have this combined type of isolator/socket on the unprotected side of the...
  17. K

    cooker switch with socket

    Could any of you qualified sparks please help? I am replacing a kitchen and my sparks says that to put a cert on his work the cooker circuit which is from a 32 amp MCB in 6 mm T&E to an isolation switch with a socket needs to be on the RCD side of the consumer unit.The oven switch and socket is...
  18. K

    spur off spur

    Some advice would be very much appreciated. On hacking off water damaged plaster in a conservatory I found that the feed for 4 double sockets along the wall had been taken from a single spur in the adjoining lounge with a 13 amp FCU in between the lounge spur and the 1st conservatory socket...
  19. K

    boiler problem

    Many thanks----Agile & Gas4you I was wrong about 2 things boiler is 4 years old and on actually timing the boiler on heating and water setting it switches on and off about every 50-70 seconds. Thanks again for speedy assistance Sorry previously put this as a new post not a reply.
  20. K

    boiler problem

    Please help I have a 2 year old Gloworm Micron 60FF boiler controlled by a Lifestyle LP241 clock unit.For the last couple of days without using timer settings and just selecting hot water the boiler will only stop ,on for about 1 minute , it sometimes re lights automatically but then goes out...