  1. B

    Brick Pillar - Point / Rebuild / Partial Rebuild?

    Thanks for replies...
  2. B

    Brick Pillar - Point / Rebuild / Partial Rebuild?

    The pillar pictured below has been like this for years. You can see it was previously "re-pointed" badly. However, since cutting down 2 big trees, the pillar hasn't since moved and the gap has actually closed back up. Do you think we should rebuild the pillar or would it be possible to...
  3. B

    Double Pole Neon Switch

    Yeah I have a multimeter but he is coming back in 2 weeks to sort a few other things out anyway. Unfortuately, I wasn't there when he did the check, only my wife and his handwrting on the report is awful :) I just thought it seemed odd...
  4. B

    Double Pole Neon Switch

    thanks for the quick replies, i'll check it.
  5. B

    Double Pole Neon Switch

    I had a periodic check done on my house and 1 fault the electrian mentioned was "the neon in the double pole switch located in the bathroom does not function correctly". But it does work, ie. it comes on when the switch is "On" and goes off when the switch is "Off". I am now confused and...
  6. B

    Fencing Material

    Hi, I am after a large amount of fencing materials: 35 panels 36 Concrete posts 36 concrete gravel boards etc Can someone recommend a supplier in the midlands, coventry/birmingham area ? Thanks, Andy
  7. B

    can't increase the pressure by much

    When you turn on the cold tap in the kitchen, do you get poor water pressure ? It sounds like this might be the case i.e. your cold water mains pressure is 0.75 bar. That is very low but not unheard of...
  8. B

    mid pressure valve

    Does it look like this; If so, it is a "Mid position valve", not a "Mid Pressure valve" The "Little Handle" enables you to manually move the valve, usually between DHW and CH or both. Normally, there are no settings on these valves as they are controlled by timers etc. Perhaps just...
  9. B

    my boiler\\\'s in the red!

    The system should be filled when cold to the pressure specified in the manufactures instructions. (Probably around 1 - 1.5 bar without checking the MI). It is normal for a slight increase in pressure when the system warms up. However is the pressure is going in the "Red", you probably have a...
  10. B

    Water Pressure Valve

    The PRV (Pressure Relief Valve) will reseat itself okay. However, when the PRV discharged itself, it shouldn't really discharge back to zero pressure. Try to fill the system back up to around 1 - 1.5 bar. If the PRV is leaking, you may be able to reseat the valve by opening and closing a...
  11. B

    Baxi Bahama 100 Help Required

    Yeah, the one you which you have just turned on.
  12. B

    Baxi Bahama 100 Help Required

    Close the lockshield valve (the one under the cover) right down and open it slowly until you hear some flow. I would expect that the lockshield is open too much and stealing all the flow from the other rads when you "turn it on".
  13. B

    water problem

    Did you have a vented system (small header tank in loft) prior to the combi ? If the heating system has been converted to a sealed system using old pipe work, probably the higher pressure had caused an old joint to fail...
  14. B

    Monobloc Tap

    This type of filter is easy to fit (although this model is probably not the best) http://www.screwfix.com/app/sfd/cat/pro.jsp?ts=95635&id=18834 They can be fitted to the rising main and will treat both cold and DHW. I also noticed this...
  15. B

    laminate flooring for kitchen

    Laminate is far from ideal in kitchen areas. Where the boards are joined, any exposure to moisture or water spills will lead to the swelling of joints. In addition, laminate should be fitted on top of underlay as a floating floor. The floor should not be fixed with neither nails or screws...
  16. B

    What is the correct height of vent pipe?

    12" is okay from the top of the water level to the highest point of the vent pipe. The height of the F&E tank must obviously be the highest point in the system. Presuming if this is happening from cold and effecting both DHW and CH modes, it sounds to me like you have one or more of the of...
  17. B

    Combi-boiler problems

    Like I said, check the PRV. Should be a pipe runnig from the boiler outside or into a tundish. Water must be leaking from somewhere. The scale/crud I mentioned would be keeping the PRV open and letting water open.
  18. B

    Combi-boiler problems

    How long does it last when topped up 1 hour, 1 week ? If you are losing pressure over a longer period and you are getting losts of air/hydrogen when you bleed the rads, you might have lots of sludge in your system. If you are losing pressure over a short period, check if the pressure...
  19. B

    quotations

    I myself would never quote for a job like this over the net or phone. Rough guess: As long as your boiler was up to it and didn't need attention I would say £300-£350 + any parts you forgot / didn't think you needed. It sounds like you want a new central heating system installing minus...
  20. B

    quotations

    Sorry for the questions... "Install 6 new rads". Are these completly new (no existing pipework) or do they only need changing over ? Do you live in a house or bungalow ? Will you supply the rads ?