Search results

  1. J

    No EPC - Advice Please?

    Hi, Not sure if this is the correct place to post, but.... I purchased a property back in 2012, which I am now looking to sell. My estate agent has come to do the marketing and has found that there is no EPC registered for the property, despite it being a legal requirement to have one in order...
  2. J

    Correct fitting for 3/8 Alkathene

    Hi, I have what I believe is a 3/8 Black Alkathene feed (I measured it at around 17mm) to my 1980's built house. At the moment it goes into the stopcock (15mm copper on the other side), but this is seized so can't be turned off. I've fitted a new stopcock just downstream of it, but feel i...
  3. J

    Terminating SWA in Meter Box?

    Good afternoon all, I'm after some suggestions from some of the more experienced sparks on Terminating SWA in the meter box. In the past I've used a Wylex 100A fused switch and never had a problem with the DNO or Meter operator. However, on this occasion the Meter operator has refused to...
  4. J

    Ideal Icos DIY PCB Replacement?

    I've got an Ideal ICOS HE24, which appears to be dead. There is no output on the LED display and switching the power switch doesn't make any difference. There is 240v going into the PCB box and the fuse is good, so based on other peoples issues, I'm going to assume that the PCB is faulty...
  5. J

    Nail gun Advice

    Hi, I'm currently working on a renovation project of a 4 bedroom house. The place has been completely gutted and replaced and I'm now working on the final bits of the 2nd fix. Having found an auto loading screw gun an absolute godsend for plasterboarding the ceilings and walls, I thought...
  6. J

    Soil Pipe questions

    I am currently re-designing my first floor bathroom to incorperate an ensuite to one of the bedrooms. In doing this I will need to change the soil pipe configuration, so that the pipe from the bathroom and ensuite toilets runs under the floor. The existing soil stack is shown in the top...
  7. J

    Speedfit conduit questions

    Hi, I'm currently in the process of renovating my house, part of this is including installing a new central heating system. I'm having a plumber install a new combi boiler and i'll then do the rest from there. I'm intending on doing the whole lot in speedfit plastic pipe, which all 3 plumbers...
  8. J

    T&E to outbuilding?

    I need to supply power to a barn that we have just had built - when it was built the builder installed a service duct between the house and the barn. The cable run will need to be about 50 metres, can you used twin and earth for outside runs in conduit / ducting? The barn itself has already...
Back
Top