Search results

  1. C

    britoney 80 Chaffoteaux boiler

    i have said boiler in a set of flats.unfortunately the boiler has had a beating several times resulting in system water loss every time. It has been a case of re setting the valve body and re filling, there have been several times on move ins where a rad has been moved resulting in the same. It...
  2. C

    britony 80

    the flow switches have been replaced but you mite have something with the thermistors if the thermistor is faulty could it shut the 3 way valve if so this may well be the fault
  3. C

    britony 80

    the air bleeder foams after the system has been open and yes if u remove the screw the pump is moving ok
  4. C

    britony 80

    it has self bleed but i feel the boiler is air free and after doing all what i've said thought about a pump prob so i removed it to check whether the impellor had broke of it no joy
  5. C

    britony 80

    i have a britiony 80 combi that has suddenly stopped working on heating hot water is fine so i changed the flow valves then followed the service fault diagram that says change the diverter valve or 3 way valve no joy. the pipe up to the ch isolator tap on left is hot up to the tap pump is...
  6. C

    two way pir

    could anybody help with a diagram to allow two lights to be turned on at the same time by two separate pir s or is as simple as linking the live wires together.
  7. C

    flymo turbo compact 380

    checked with supplier belt correct and there is no tensioner
  8. C

    flymo turbo compact 380

    just bought a new belt as the old one came off thought id treat it to a new one but bloody thing still comes off can any body help
  9. C

    sockets

    what is the recomended height for light switches and plug sockets and will it make a difference if its an extension to an old house compared to a new house
  10. C

    indesit omega 1000 eco sense

    thankyou for the explanation and after that advise about the consumer unit i will take note i will try to service the brushes soon but as you can know it's not 10 mins of a job will let you know how i get on busy at min thank you once again
  11. C

    indesit omega 1000 eco sense

    well how come it washes and it spins empty if the brushes are done it would not run at all ?
  12. C

    indesit omega 1000 eco sense

    its about 8 years old
  13. C

    indesit omega 1000 eco sense

    i have machine above it will wash but not spin with load in but its ok with out can anybody help
  14. C

    split load consumer unit

    thanks breezer re-wired consumer unit keeping mcb 1 to earth 1 to neutral to1 and so on.everything ok you were wright thanks for that had to chip a brick out though to extend the wires laziness does no prevail :lol: have a happy new year !
  15. C

    split load consumer unit

    thank you breezer i will look at later today but that sound like the problem an imbalance will let you know thank you for your help :D
  16. C

    split load consumer unit

    if i don't un wire anything at all but remove the mcb itself to the protected side the fault goes away checked and double checked thanks though breezer :(
  17. C

    split load consumer unit

    i have changed my standard wired fuse box to split load with rcd.all my plugs,shower and garage are protected by rcd fine the cooker and lights are not.its ok up to the time i switch on an item that is not protected by the rcd off goes the rcd turning the house off except for the unprotected...