  1. B

    Selwood Childrens Playset

    Hi all I have recently bought a playset from a company called Selwood. Now the wood used is Chinese Cedar. It comes pre stained with a light covering of a water based stain. The stain is for colour only. The wood has not been treated for protection etc. The owners manual says that I...
  2. B

    Continuity of CPC

    guess you have never used a mobile phone to txt in short hand b4 hav u, lol, what a TFI
  3. B

    Continuity of CPC

    thanks for the replies, its easier to understand when a spark explains stuff to you rather than a lecturer reading str8 out of a book!
  4. B

    Continuity of CPC

    Hi all can someone please explain to me why it is essential to verify the continuity og the cpc (R2) before carrying out an impedance test on a socket outlet install. Many thanks
  5. B

    Design Stage

    thanks for all your help guys, appreciate it
  6. B

    Design Stage

    hi all could someone please explain to me why i need the follwing information at the design stage of an istallation - - Prospective earth fault current (I) - The value of external impedance (Ze) - Assumed current demand of the installation - Disconnection times of certain light...
  7. B

    EAL Certified Domestic Installer Course

    You know full well all most tutors care about is getting people out the door with the bare minimum so they can get the next bunch of soon to be dangerous monkeys in for their 5 day im a spark now courses. who said that i was doing a 5 day course? ive been studying to become a spark for the...
  8. B

    EAL Certified Domestic Installer Course

    hi all im currently doing the above course and im struggling with a few questions. im fine with the electrical questions, since im studying to be a spark, but on the course you get asked questions which i have no idea about, here is one example - - Give TWO reasons why it is necessary...
  9. B

    A few questions

    thanks for the advice, really appreciate it
  10. B

    A few questions

    hi all i need a bit of advice. could someone help answer some of these questions please 1. if you have the 17th edition and are part p are you only allowed to sign off your own work. and if you want to sign off someone elses work, or do periodic inspections on domestic properties do you...
  11. B

    Underground Drainage

    can no one help?
  12. B

    Underground Drainage

    the main drain is plastic and so are all the 4" pipes that attach to it.
  13. B

    Underground Drainage

    hi all i am fitting a new sink to an extension on the house. all internal pipework has been done. the problem i am having is on the outside. because we have a manhole/drain near to where the sink is to be fitted i was advised to take the waste pipe from inside the extension to the...
  14. B

    Physics Question

    Thanks guys Now why couldn’t our physics teacher explain it in simple terms like u guys, instead she rather stand in front of the class and read from a “how to teach physic when you have no idea what your talking about” guide book for teachers!
  15. B

    Physics Question

    So would you go with "b"? also do u go with bigger or smaller fuses if your circuit is 60 amp, just trying to understand how all this works, sorry for sounding thick.
  16. B

    Physics Question

    Hi all I’m doing an assignment for physics class and its to do with electrics. The question is: Which one of the following would cause an unsafe situation? a. A 6 amp fuse in a 60 amp circuit b. A 60 amp fuse in a 6 amp circuit c. A 60 amp wire fuse in a 80 amp circuit d. A 6 amp...
  17. B

    TN-C-S

    Thanks guys, i needed to put it into a contract, i'll just refer to it as PME. Cheers
  18. B

    TN-C-S

    Hi ya Could someone tell me what the legal term for TN-C-S is. Many thanks