Search results

  1. J

    Replacing extractor fan with timer version

    Will stick to just a standard fan then as would have to rip the wall/ceiling apart to swap to a 3 core cable
  2. J

    Replacing extractor fan with timer version

    Get rid of the fan switch and have the fan turn on/timer from the light switch
  3. J

    Replacing extractor fan with timer version

    My bathroom extractor is making a right old noise in a house recently moved into so looking to get a new one. At previous home had an extractor fan with timer when the bathroom lights was switched on. This was wired from the light ceiling rose. Got grid switches at new place and struggling to...
  4. J

    Utility room - washing machine and tumble dryer wiring

    Yes they are both for the washing machine. That's how they were since moved in a few months back. There are 2 cables going to the double socket. The MCB for the circuit is 32A
  5. J

    Utility room - washing machine and tumble dryer wiring

    Had some work done to increase size of utility room so both a tumble dryer and washing machine can fit next to each other. Currently the washing machine is wiring into a FCU as seen in the picture. Would also like to have the tumble dryer (condensing heat pump) also wired in below where the new...
  6. J

    New home - totally confused by system.

    Got an engineer coming Monday to service boiler and the 2 cylinders. Figured the pump is always running when HW is on even when the boiler isn't heating HW. Do the cylinders work in tandom draining together or separately?
  7. J

    New home - totally confused by system.

    Moved house and totally lost to on our heating/HW system. There is a sealed system boiler (potterton promax SL) and 2 unvented 120l water cylinders. 5 bedroom, 3 floor house. 3 shower rooms. Unsure if the cylinders are linked or work separate. Also noticed pump is always running
  8. J

    2 unvented cylinders?

    Recently i went to view a 5 bedroom, 3 storey house and while looking around on the top level noticed a small door and had a look. Behind was 2 unvented (Gledhill i think) 120L cylinders. There was also 2 white expansion vessels and also a red expansion vessel? Does anyone know how this setup...
  9. J

    Correct setting for auto bypass valve

    have totally closed/fully screwed down the ABV and the pipes are still heating up (although unsure which one shouldn't be)
  10. J

    Correct setting for auto bypass valve

    Been trying to figure the correct setting for the auto bypass valve fitted my heating system. The pump is a Grundfos Alpha2 15/60 and the boiler is a Worcester 15ri.
  11. J

    Central heating pump affecting my subwoofer?!

    Tried one of these but has not cured the problem. http://www.amazon.co.uk/kenable-Surge-Protected-Extension-Protection/dp/B003OSV1GC/ref=sr_1_1?ie=UTF8&qid=1452167383&sr=8-1&keywords=surge+protection+extension+lead+rfi
  12. J

    Central heating pump affecting my subwoofer?!

    No, the pump was installed not long before i had my new boiler (just over 3 years ago)
  13. J

    Central heating pump affecting my subwoofer?!

    Over the last couple of months i have started to notice when my central heating system switches off i sometimes get a couple of loud thumps come though my sub-woofer. My heating system is a normal boiler (Worcester 15Ri) coupled with an unvented hot water cylinder. Both hot water and heating...
  14. J

    Replacing Honeywell t6360b thermostat - wiring?

    Thanks that worked great! No just the standard version. Totally lost on that the advanced adjusting the setpoint using present temprature does lol
  15. J

    Replacing Honeywell t6360b thermostat - wiring?

    I want to replace the old Honeywell T6360 thermostat with a drayton digistat+. I thought it would just be 2 wire but when i took the cover off the honeywell i was faced with 3 wires. Can anyone please help me with which wire goes where. :?
  16. Untitled

    Untitled

  17. Untitled

    Untitled

  18. Untitled

    Untitled

  19. thermostat

    thermostat