Search results

  1. B

    Roof Insulation - Losse fill or Blanket?

    Hi I have a garage i am converting into a games room. The new recently completed roof is an Asymmetrical pitched one that will allow for storage above the garage so a ply floor will go down - existing joists are more than enough, they are the size of the normal first floor joists. It was a...
  2. B

    Recommend: Bullet or dome camera with IR with 5- 20mm VL

    Thanks for the heads up. Looking at a AIR45/50. 50mm. I see it has IRs, but looking at the manual doesn't seem to be switchable, so how do you get on with the light level the IRs come on at? Any problems? How long is the cable that comes out of the back for the power and coax? I have...
  3. B

    Recommend: Bullet or dome camera with IR with 5- 20mm VL

    no 100% sure, but don't want to risk 18mm, may not be quite enough but 20mm will certainly be enough. Can almost read a plate in good light.
  4. B

    Recommend: Bullet or dome camera with IR with 5- 20mm VL

    Hi I have a simple DVR set up, with a 5-15mm dome camera looking onto the entrance of our drive into the cul-de-sac. However, its just not quite near enough to get number plate recognition of passing cars. I just need a little more zoom. Can anyone recommend a 12vDC Camera, bullet or Dome...
  5. B

    12v PSU mains to bateryy change oibver porblem

    Hi I have a CCTV PSU. Looks well made, multiple outputs with ply fuses, LEDS to indicate health and battery backup. However, i put in the battery today, failed the mains and there was a split second blip which caused the DVR to reboot. Cameras I can live with, but not the DVR. Any one...
  6. B

    Veritas R8Plus and AG6 +12V fault

    This turned out to be nothing more than a faulty Panel in the end. It just would not deliver the power to the battery or aux 12v. Changed for a Galaxy, no problem. Been fine for weeks now.
  7. B

    CCTV PSU Request

    Hi Its a lot more money and more waste from converting from DC to Ac then back to CA again :-) I did think about it though :-) Cheers John
  8. B

    CCTV PSU Request

    Okay so looks like i will get this one and then modify the PCB to i have a 7A output and 5 smaller ones. http://www.procctvstore.co.uk/products/PSUB9WAY?gclid=CJeD5vXb8MECFSrHtAodzAwAcA Cheers JB
  9. B

    CCTV PSU Request

    Hi Anyone know of a unit that will fit this need please? Its for a PSU for my house to feed some cameras and and a DVR - only one needed. I would like: - 1 - To feed cameras and DVR (circa 10A @12Vdc) from the same PSU 1 - To feed cameras and DVR (circa 10A @12Vdc) To...
  10. B

    Glow Worm Boiler - British Gas 330 Fault Code Issue (long)

    Hi, there are about 15 rads in the property. Early 80s build. I am going to phone the manufacturer today to check how the boiler determines this type of fault. May help me understand what the issue is better. I am pretty sure it is related to EVO in some way, i just need a better...
  11. B

    ANy thoughts About this CCTV kit

    Hi anyone got any good or bad to say about these: http://hdcctv.co.uk/products/960h-8-channel-professional-real-time-dvr-xr960d8 I am looking at installing the following XR960D8 – 8 channel DVR Y1QD10ZS – 600 TVL Min Dome Complete with brackets XC960VV – 700 TVL vandal proof...
  12. B

    Veritas R8Plus and AG6 +12V fault

    Battery is fine, i tested it with battery tester ACT unit, shows about 4AH left in it. I would also anticipate other troubles if power was dropping on the supply for the devices, like tamper or alarm when set for the PIRs. I will check though the next time i am there. I did thin about...
  13. B

    Glow Worm Boiler - British Gas 330 Fault Code Issue (long)

    Thanks for the replies so far. It sized according to the number and size of rads it is feeding, if they were all turned on together. What are the thoughts about lock shields. They are standard Honeywell lockshileds, all new. Closest rad is shut down to 1/4 turn from closed, while furthers...
  14. B

    Veritas R8Plus and AG6 +12V fault

    Hi, thanks for coming back. Yes i saw that they no longer used fuses. wondered the same about it shutting down. I need to be there, when it is happening to confirm. All cable is not accessible. Doing an insulation resistance test (not at 500v) yields no low readings between conductors...
  15. B

    Veritas R8Plus and AG6 +12V fault

    Hi Recently i had to replace both the panel and the bell. The bell fist because the strobe had stopped working. When i replaced the bell, i then found the strobe output was locked on from the panel - disconnected outputs and had a permanent neg applied at the panel. The busted strobe...
  16. B

    Glow Worm Boiler - British Gas 330 Fault Code Issue (long)

    Hi I have the above boiler, i recently installed a Honeywell Evo system on all rads. So i now have control over all rads and hot water. We recently moved in so have no benchmark of operation before i made the change. I am not a Proff plumber but have done plenty of plumbing on past...
  17. B

    Buzzing Light No Power - How?

    It is buzzing from the lamp, both of them infact. I have the same low energy lamps throughout and these were the only ones that buzzed. I realise that i have not stuck 500v across it, but i would have thought a low insulation resistance, of that magnitude, would have shown up on my multM set...
  18. B

    Buzzing Light No Power - How?

    Hi I wonder if anyone has experienced this and may have an answer please!? In short, when any of the switches disconnects the switched live to the lamps, the lights go off, but a faint buzzing sound can be heard from both lamps – found 30-60Vac between Live and earth – only happened once...
Back
Top