    a thin layer of plaster is coming off when painting.

    Many ways to skin a cat. Never ever had a single issue with emulsion not adhereing after coating with a light coat of watered down PVA. I used Evo Stick wood glue in my bathroom due to peeling and flakyplaster like the original poster described , 2 years later and it still looks as good...
  2. C

    a thin layer of plaster is coming off when painting.

    Never had a problem with paint not sticking when the walls have had PVA on them in fact the total opposite. The emulsion becomes extremely durable and easy to overpaint. I have found watereddown emulsion leads to repaint problems in the future. The emulsion peels, crazes and also wipes off...
  3. C

    a thin layer of plaster is coming off when painting.

    Paint the walls with some watered down PVA adhesive prior to trying to paint them ,this should do the trick. ,
  4. C

    Hairline cracks - interior wall/ceiling - matt emulsion

    I would leave it for a few months and see if anymore appear if they dont and painting wont hide the crack, then use a stanley knife to enlarge the crack slighty cutting it into a V fill and sand as neccessary and repaint .
  5. C

    Advise - Extending BT cable outside to run downstairs

    In all honesty I never got a tickle from a PSTN line in anyway in 3 years even when using the non BT approved spit on your finger to to see if it fizzes method of seeing if a line had voltage on it or not :D Much quicker than using a multimeter!!!!!!!!
  6. C

    Ideal Isar HE24 leaking badly

    I take it a PRV is a pressure release valve ? I know nothing about boilers. Its a 2 year old David Wilson house I hope the boilers installed properly !!!!!!!! As properly as the plastering has been done more likely :)
  7. C

    Advise - Extending BT cable outside to run downstairs

    The REN rating of a line is generally 4 . All phones faxes etc have a REN rating , the number of phones etc etc on one line shouldnt exceed 4 as they may not ring , they generally do though :) PSTN and Broadband are 50 volts DC ISDN is 100 volts and will give a little tickle. As an...
  8. C

    Ideal Isar HE24 leaking badly

    1.1 bar is what the guage reads
  9. C

    Aqualux Steam Cabinet shower

    Yes what would you like to know ? I worked for Aqualux as a service engineer and know these inside out. There are some modifications you need to do to parts like the divertor valve prior to installing to ensure they work properly for more than a couple of months.
  10. C

    Ideal Isar HE24 leaking badly

    Hi there I have the misfortune to have an ideal Isar HE24 combi boiler. I opened the airing cupboard door today and found it was leaking heavily. I removed the front cover and base cover and the leak looks to be coming from the black plastic with red front compnent which is located at the...