Search results

  1. R

    Alpha CB24 diverter Valve Removal

    Hi Nickso, when you say o/ring for ''back plate'' does that mean where the Diverter Valve is unioned to the heat exchanger part,, thanx Rob
  2. R

    Alpha CB24 diverter Valve Removal

    Hi again, Thank you nickso for your valued help ,,, Rob
  3. R

    Alpha CB24 diverter Valve Removal

    Hi nickso, Can you please tell me the sizes of the four union nut washers so i can order ready thxn again rob
  4. R

    Alpha CB24 diverter Valve Removal

    Hi , Thanx for your reply, im going to renew the whole diverter plus the collar at manifold inlet, the part the two screws are situated to join collar to diverter valve. Thanking you rob
  5. R

    Alpha CB24 diverter Valve Removal

    Hi, Thanx a lot, i did think it was the bottom one facing me. but thank you for your reply... rob
  6. R

    Alpha CB24 diverter Valve Removal

    Hi All, ''Firstly'' i have a water leak directly at the Flow Switch,would renewing the Switch possibly stop leak.? If the answer is no to my 1st question, ''Secondly'' i have prepared ready to renew the Diverter Valve Complete. I Viewed a Video on this, ie undoing the 'four union nuts,' 'pulling...
  7. FLOW SWITCH

    FLOW SWITCH

    RENEWING
  8. INLET MANIFOLD COLLAR

    INLET MANIFOLD COLLAR

    RENEWING
  9. DHV

    DHV

    RENEWING
  10. alpha Cb 24 Diverter Valve

    alpha Cb 24 Diverter Valve

    renewal
  11. R

    Alpha CB24 combi gas Central Heating Boiler water leak

    Hi Everyone, Can you please guide me on the following-- i have a water leak at the Diverter connection on my Alpha CB 24 combi gas Central Heating Boiler. Would anyone of you on forum know where the cold water on/off valve is, looking from the front of the boiler.I have an idea following the...
  12. R

    ALPHA CB24 COMBI GAS CENTRAL HEATING BOILER

    I got no probz with heat, its just that it comes on when in the off position :oops:
  13. R

    ALPHA CB24 COMBI GAS CENTRAL HEATING BOILER

    Hi, My combi boiler for some reason just comes on, even though it is not switched on at the little ratchet switch on the clock, and i have to switch it off at the inline main switch. Does anyone have any idea why this happens, just hope its not a ghost please help ...Rob :?: :shock...