the glass fuse in the wiring centre in my airing cupboard started blowing randomly, after inital fire up of CH after the summer months, I have a standard gravity fed system?

changed motorised valve, (v4073a) and pump (grundfos) but still blows fuses randomly??

I have sort of worked out that if I switch on the CH only and let it get up to temperature and pump has switched off, and then hit the HW button fuse blows....... and vice versa

Hope above is clear

Any help would be appreciated
 
Sponsored Links
Sponsored Links
something is drawing more than 2 amps in the circuit. you say you have replaced the pump and MV, so therefore something else must be drawing the current. if it only happens when you select hot water, then you need to think what is on the HW side.
what exactly is your system? is it a pumped CH gravity hot water or fully pumped? you say its a standard gravity system, but do you mean open vent?

does the pump come on for the HW?

normally, Heating systems are fused with a 3 amp not 2...
 
is it a pumped CH gravity hot water or fully pumped? you say its a standard gravity system, but do you mean open vent?

does the pump come on for the HW?

normally, Heating systems are fused with a 3 amp not 2...


i think the (v4073a) 3 port gives it away. ;)
 
something is drawing more than 2 amps in the circuit. you say you have replaced the pump and MV, so therefore something else must be drawing the current. if it only happens when you select hot water, then you need to think what is on the HW side.
what exactly is your system? is it a pumped CH gravity hot water or fully pumped? you say its a standard gravity system, but do you mean open vent?

does the pump come on for the HW?

normally, Heating systems are fused with a 3 amp not 2...

Hi, thanks for your response, I am a CH/HW novice, but i am almost sure that the system is a Pumped CH gravity system, the pump does come on for the HW, but goes off when up to temp, which i believe is correct??

I have 1 x honeywell v4073 mid position valve, (new powerhead)
 
was it doing it before you changed th head?

fuse blew when switched on after summer, motorised valve was not working, so changed that, that is working ok now, but fuse still kept blowing, so i was advised to have the pump changed, which i did, but fuse still blows??
 
your wiring centre , does it have " honeywell smartfit " written on the front cover?
 

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 
Sponsored Links
Back
Top