is it boiler problem?

Joined
18 Jul 2011
Messages
2
Reaction score
0
Location
Belfast
Country
United Kingdom
hi all,
when the hot water is running for a length of time even the boiler mode is hot water only,I found the radiator is warm.it seems like the CH work.
i am confused with it. is there a problem in the boiler or the set up is not correct.
could anyone give me a idea about that?
the boilder is BAXI combi 50e
many thanks...
 
Sounds like the diverter valve is "letting by", ie passing water to radiators when hw on.
Diverter valve needs service kit or replacement.
 