Best way to control UFH?? Well, it depends if you have a large thermal mass ie pipes in concrete screed, overlay or thin screed.
Most common systems are concrete screed, so I'll explain that; Because it's radiant heat, 17 feels like 21C, so set your room thermostats to 17C for when you want heat & 5-8C overnight or periods when you don't want heat on 'set-back'. Large thermal mass UFH is very cheap to run, but running it 24/7 is plain daft, use 'set-back' room thermostats on thermal mass systems or even better on a WC system.
Of course overlay or thin screed systems are more expensive to run & are controlled more like a radiator system.
Having UFH in a Bedroom zone is also daft, much better to have standard emitters in these areas.
Most common systems are concrete screed, so I'll explain that; Because it's radiant heat, 17 feels like 21C, so set your room thermostats to 17C for when you want heat & 5-8C overnight or periods when you don't want heat on 'set-back'. Large thermal mass UFH is very cheap to run, but running it 24/7 is plain daft, use 'set-back' room thermostats on thermal mass systems or even better on a WC system.