I've had a new dual RCD CU fitted and I have a few questions about the installation.
Am I being too sensitive or does this sound like a poor job?
Many thanks for any answers here.
- The MCBs are labelled incorrectly.
- Some of the neutral cables don't share the same slot number as their corresponding lives.
- I have a 10mm SWA running to my summer house. He's added an earth rod at that end, which I guess is no bad thing. However, at the house end, he's used a 1.5mm earth from the gland to the CU
- I have two radio linked smoke alarms. They're both on the same RCD
- The load balancing seems all wrong. I have a 45amp shower, cooker, kitchen ring and some lights and smoke alarms all on one RCD. The other RCD only has bedroom ring, central heating controls, and lights on it
Am I being too sensitive or does this sound like a poor job?
Many thanks for any answers here.