Fireproofing RSJs in ceiling

Joined
29 Jan 2008
Messages
2,050
Reaction score
410
Location
Liverpool
Country
United Kingdom
Hi folks,

I have RSJs in the ceiling under which I plan to fit a flush ceiling in plasterboard.

Do I need to box the RSJs with fireproof plasterboard put up the sides too, or can I just put it across the bottom in line with the ceiling?

If it’s the latter, does the whole ceiling need to be FP plasterboard or can I centre the 1.2m side of the plasterboard so that there’s a width of 450mm of pink plasterboard either side of the RSJ?

I found this thread but seems to be a bit conflicted, so any help gratefully received.


https://www.diynot.com/diy/threads/fireproofing-rsj-in-ceiling.506498/


Thanks
Andy

ACD8DCD9-1592-4576-B6F6-8727D59BF757.jpeg
 
Sponsored Links
Normal 12.5 board and skin gives 30 minutes, so as long as that is what's used on the ceiling that protects the beam too
 
Sponsored Links
Ah ok thanks, I have plenty of 12.5mm PB and it will be plastered, so I’ll run with that. Thanks again
 

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 