Recent content by Airiasas

  1. A

    Tiling downstairs bathroom

    I tried going the other way and I did not really like how it looks cause the 3 line of tiles would have to be cut almost in half an it looked a bit odd and not symmetrical. If I would try to make it symmetrical horizontalally it would even look worse as tiles would have to be cut on both sides...
  2. A

    Tiling downstairs bathroom

    Hello everyone, I am tiling my downstairs toilet. Tiles will be laid on concrete floor. I am looking some guidance regarding tile pattern. The pattern that fits the best at this area in my opinion is this one: What do you guys think of this pattern? Can you give my any advice or guidance on...
  3. A

    Wiring a bathroom extractor fan with a timer

    Which one should I use? I have seen they have different AMP ratings? I have access to the loft and I can reach the cables from there. I would not be able to put the junction box right above the light fitting as the light is fitted at the beginning of the flat roof, but I would be able to pull...
  4. A

    Wiring a bathroom extractor fan with a timer

    There is space, but I would prefer to make it nice and neat if there is a way to do that. Also, the wiring diagram that I have done is it correct? Sorry, it is a bit messy.
  5. A

    Wiring a bathroom extractor fan with a timer

    Good evening everyone, So I am wiring a Turbo Tube Pro 100 4 Inch Inline Fan with Timer. I need some guidance on how to connect some of the wires. The extractor fan should turn on as the switch is pulled to switch a light on, and after the light is turned off fan should run for a set amount of...
  6. A

    Wylex old push in fuse replacement

    Thanks for your reply. CU will be upgraded once funds will be available, as I just moved in and a lot of stuff needs to be repaired. I opened the led power supply and IR switch and both were black inside, so they caused the failure for some reason I guess.
  7. A

    Wylex old push in fuse replacement

    I am not sure how this house is wired as I recently moved in but it still has old wylex CU So I am not sure if it happened because of the humidity in the bathroom this morning as when my girlfriend tried to switch on LED mirror using IR sensor something just popped inside. I took the mirror...
  8. A

    Wylex old push in fuse replacement

    It is fine right now all sorted, I took the fuse apart that is why it is missing those pins. I bought a new fuse from the link that I posted, installed seems to be fine. The old fuse was blown by bathroom mirror, I will have to look at it how it is wired cause it cut of all sockets and lights on...
  9. A

    Wylex old push in fuse replacement

    Good afternoon everyone, Wylex old push in fuse is gone and needs replacing. I believe they hav le been discontinued. I have attached the picture of the old fuse. It says it a 5amp fuse. My question is can this be replaced with a fuse from Screwfix? Link...
  10. A

    Nest 3rd Generation wiring.

    And finally just to check both ground wires Green and yellow (from the fused switch) and Green and yellow (from the boiler) go to the same Earth connection in the Nest heatlink? Thank you.
  11. A

    Nest 3rd Generation wiring.

    I am going to wire the nest thermostat to T1 & T2. Boiler connections: LR: Grey N: Black L: Brown Ground: Green and yellow What would be nest Heatlink connections: N: Blue (coming from the fused switch) L: Brown (coming from the fused switch) and Brown (coming from the boiler)? 1: Nothing? 2...
  12. A

    Nest 3rd Generation wiring.

    Hello everyone, I have a Worcester Greenstart 24i Junior combi boiler installed in my house. I'd like to wire a nest 3rd gen thermostat. The programmer wiring: The thermostat dial wiring (RTS1): It looks like the fused switch is wired in a programmer unit: So switching off fused...
Back
Top