Recent content by blacknesh

  1. B

    LED lighting

    I did mean w not kw, I think il just leave it with the eletrican and try different bulbs as time goes on, many thanks anyway,
  2. B

    LED lighting

    There good, you don't need your heating on, and I feel a little more tanned
  3. B

    LED lighting

    I did mean 40kw of lighting I was thinking 8 x 5kw led = 40kw, guess this was wrong,
  4. B

    LED lighting

    I'm looking to get led spotlights installed, but I'm a little lost by the amount of spots lights required, my living room is roughly 4m X 5m and currently have a 13w light in the center of the room, my friends brother is a electrician and said I would need 8 lights, but if I installed that with...
  5. B

    Worcester time clock

    Yer that's ok I'm a plumber/gas, the clock cost £140 with the vat, and I charged 80 to supply and fit, so £220 total, you could get a different clock instead if you wanted, the worcester one lets you set times for the hot water preheat, not really worth getting but the customer wanted it, only...
  6. B

    Worcester time clock

    No way to reset, it ended up with a new clock, this is also the boiler display, did you have a powercut by any chance
  7. B

    100kw domestic boiler

    Yer clearly didnt read it correct, but why bring oil into it to confuse matters.
  8. B

    100kw domestic boiler

    45kw, didn't realise? went did that come out, as last I knew it was 70kw and pipe sizing no bigger then 35mm?
  9. B

    100kw domestic boiler

    They could do a factory with offices needing this kind of kw, the rads would be normal sizes just lots of them, the biggest boiler I ever fitted was a 42 kw, as a domestic installer you can't exceed 70 kw anyway, you asked him if he's gas registered?
  10. B

    100kw domestic boiler

    Sure he meant 100.000 btu not kw
  11. B

    Worcester time clock

    Worcester green star cdi, hot water clock flash 026 there's nothing in the book or the programmers instrustions which is a dt10rf, it's only a year old and I see only one other person on the web seems to of had this problem, but no one as posted a answer
  12. B

    Builders opening

    I was going to brick up a builders opening and fit a flueless fire In its place but am I right in thinking the builders opening still needs ventilation to prevent damp, if this is the case is there anyway around this as i can't have and vents near the flueless, many thanks all, and merry Christmas
  13. B

    brick effect tiling

    evening all, what size adhasive spreader do you tend to use on ceramic tiles 400x150, also the window reveal is 230mm deep which means i will need to brick effect on this too?, i have seen bathrooms with brick effect around the room, and single tiles laid on the base of the window reveal and the...
  14. B

    Gas hob regs

    Found it will post there next time no hard feelings
  15. B

    Gas hob regs

    Ok I am gas reg I don't know what the cc is if you point me in the right direction I will post in there from now on