    Radiator not Heating up.

    Took off the lockshield valve and let water pour out into a container for a bit then put it back on. Checked boiler to make sure pressure was still OK or if it would need adjusting. Radiator heats up now.
  2. C

    noise from toilet

    When you say "tapped it with a hammer", what exactly did you tap? Our toilet also makes some vibrating/fog horn type sounds whilst flushing. Not sure what to do about it. What are we looking for and what do we do to remedy the situation? Thanks!
  3. C

    Radiator not Heating up.

    OK I tried turning off all the other radiators. The offending radiator then started to get lukewarm at the top of the radiator but no more. That's as warm as it gets. Any other things I can try?
  4. C

    Radiator not Heating up.

    Thanks. The wheelhead valve would be the left hand side valve, yes? Do I just turn them until they can't be turned again or do I need to be counting the turns? Thanks again.
  5. C

    Radiator not Heating up.

    I took apart the TRV and pushed the brass pin/rod down and it came back up freely so I assume this is working OK. I'll try turning all rads off tonight and give that method a bash. All the other rads have normal valves on so am I assuming correctly that I merely turn these valves...
  6. C

    Radiator not Heating up.

    No I haven't tried this but because I don't know how to remove dismantle the plastic part of the valve? The valve is a Drayton RT212 I think. How would I do this?
  7. C

    Radiator not Heating up.

    Tried turning (opening) the LSV (counterclockwise) but still no good. Stuck as to what else we could try?
  8. C

    Radiator not Heating up.

    Thanks will give a try when husband home. Will let u know what happens. Cheers
  9. C

    Radiator not Heating up.

    Hi, recently had TRV fitted to l/room radiator by plumber. He also renewed lock shield valve on rh side too. We did call him back following day because LSV was leaking a little bit. Once plumber left we put heating on for the first time since valves replaced but l/room rad does'nt heat up. It...
  10. C

    Painting ceiling

    Thanks for the advice. Ceiling finally finished and looking fine. Decided I HATE decorating! ha ha
  11. C

    Painting ceiling

    Paint went on better this time but has small blisters on one side of ceiling. Put watered down emulsion on first then waited about 6 days before coat of dulux matt. Gonna fill these holes with a bit of pva and paint again. begining to think paint is naff. Gonna use Johnstones for final coat. Def...
  12. C

    Painting ceiling

    Cheers thanks. Sugar soaping now and gonna put watered down emulsion on tomorrow night. Will let u know how it goes. :D
  13. C

    Painting ceiling

    Hi guys. Couple of wks ago stripped ceiling of wallpaper with intention to artex. Ceiling in good nick so decided to paint. Used Dulux rich matt to avoid having to do several coats. First coat no problems but second coat blistered and peeled both coats but not all over. Advsied by friend of a...
Back
Top