Recent content by chris1850

  1. C

    Rising main stop tap problem

    I have a Victorian terraced house. The rising main stop tap no longer turns the water off properly - it slows it down but water still flows through. Presumably it needs a new washer. I assume I need to contact the water company who will have to turn the water off in the street first? Is it then...
  2. C

    PIR into an existing light circuit

    I realise that it is usual to incorporate a seperate switch for a PIR. However, is it OK to do without this and simply lead a spur from an existing circuit directly to the PIR and from there to the floodlight? I realise that the floodlight will only work when the existing light circuit is...
  3. C

    Hot water coming from cold tap!

    We recently had a problem with our oil-fired boiler. For the 2 days it was off, we relied on the immersion heater for hot water. This has not been used for a couple of years at least. Central heating is a sealed pressurised system whilst the hot water vents into the cold water storage tank...
  4. C

    Leaking oil filters

    They are probably plastic actually, and are very similar to these (last product) http://www.bes.co.uk/products/076.asp Oilman - what is involved in replacing the filters & bowls? Presumably I need to shut off the oil? What about reconnecting & firing the appliances - there are 2 boilers & a...
  5. C

    Leaking oil filters

    We have 2 inline Aluminium/Glass filter bowls fitted in our oil supply line between the tank & the boiler. Both bowls leak at the top of the glass where it joins the aluminium top. I have tried gently tightening the central bolt but to no avail. Is it possible that the filters need cleaning...
  6. C

    MCB tripping on lighting circuit

    Thanks for the replies. Yes, one PIR controls both lights. I think the suggestion to fit 300W tubes is probably the easiest solution.
  7. C

    MCB tripping on lighting circuit

    We have a small outbuilding which has a 6A MCB (B6) protecting the lighting circuit. This consisted internally of 8 x 50W halogen downlighters each with its own transformer and 2 x 100W external lights switched through a PIR. For security reasons I have replaced the 2 x 100W external lights...
  8. C

    kitchen mixer tap pressure

    It is a conventional tap with 2 heads. Thanks for the advice.
  9. C

    kitchen mixer tap pressure

    The hot water pressure on the hot water of our kitchen mixer tap has recently gone to virtually zero. Cold is fine. I have removed the tap head & cover & found that if I loosen the hexagonal nut slightly, replace the cover & tap head, all is fine. I am worried though that by loosening the...