Recent content by Exedon

  1. Exedon

    Grant Vortex Pro boiler stops firing after half an hour

    If as you say burner fan is running but no ignition photocell is normal suspect. Not high limit stat they have to be manually reset. Depending on age of your boiler riello did have a problem with photocells we changed quite a few..
  2. Exedon

    Towel rail and heater element fitting issue (dual) please help

    Loctite 55 is brilliant stuff for me way better than ptfe.
  3. Exedon

    Notable Obituaries.

    Saw him a couple of times with Booker T Jones .Outstanding guitarist on some lists only second to Hendrix.
  4. Exedon

    No Heating! Oil Heatslave Lock Out 9F 855

    Air duct end of burner push fan gently blades easily bent .
  5. Exedon

    Instant hot/boiling taps for the kitchen

    I've a customer few villages away who has a Quooker but due to our wonderful hard water she was having it serviced 3 times a year at £230 + vat a go. We have fitted a purpose made filter to it now slowed servicing to once a year.
  6. Exedon

    No Heating! Oil Heatslave Lock Out 9F 855

    With power switched off see if fan blades actually move.
  7. Exedon

    CH Pump Problem

    Magnet sticking to pipework = crud than needs to be removed. The valve appears to be a bypass don't touch it will leak for fun.
  8. Exedon

    What is this bit that's leaking? (Baxi)

    What complete and utter rubbish! As has been said it's a spring loaded safety valve ! I'm old enough to have installed many. No longer fit them, needs removing and a brass or iron plug in its place. I'd just get some old towels and do it live.
  9. Exedon

    Thoughts/advice about welding

    I've done and taught most types of welding (ex pipeline welder) It really depends on what you intend doing. Stick together a few bits of mild steel mig would do it, though Stick welding (M M A) is still worth considering. Add aluminium or stainless tig would be way to go you can also braze...
  10. Exedon

    Towel rail and heater element fitting issue (dual) please help

    Yep loose the rubber seal, loctite 55 wound on so there is plenty up to shoulder on tee Wind in job done.
  11. Exedon

    Towel rail and heater element fitting issue (dual) please help

    Assuming you mean the joint from the tee into towel warmer? Loctite 55 is what we use never had a screwed fitting leak with 55 you can even 'back' it if needed.
  12. Exedon

    Danesmoor 20/30 boiler with Selectos D42 burner

    I would suggest the clue is in the name 20/30 maybe KW? Your really need to do proper heat loss calculations to determine required size of your new boiler. Don't buy a oil boiler that starts with a W !
  13. Exedon

    Faulty CH programmer

    From memory your time switch is on a common backplate. So anything that uses that should fit straight on. We tend to use EPH stuff good price very reliable and 5 year warranty.
  14. Exedon

    advice on oversized oil boiler

    As above if you're going to with a heat pump just go for it. You can easily re jet the burner down to 15kw from memory it's a .45/80°EH nozzle needed 8 bar pump pressure you may need a disk on air intake. We have got a couple of the small Grant's running on .40/80°EH nozzles on small systems.