Recent content by flibberflops

  1. F

    Openreach - Section 40 notice

    Its a route pole No, I take no service from it I need the pole removed as I want to build in the area. I don't want payment, it doesnt have a wayleave and I am certainly not entering into one. As I understand they have no right for it to be there and I want it removed off my property.
  2. F

    Openreach - Section 40 notice

    I have served Openreach with a "Section 40" notice to remove a pole from my garden that has been confirmed has no Wayleave. Openreach have no responded to say that they cannot remove the pole because it would be "too complex of solution to try and carry out"! Can they do that? Anyone know...
  3. F

    Wayleave - two services on one pole

    Thanks for the replies.. Just to clarify... The openreach cables on are legacy phone lines and have been there for decades The openreach cables do NOT serve my property I moved into the property just 3 years ago and I don't know what the wayleave agreement with WP is exactly, I just get...
  4. F

    Wayleave - two services on one pole

    I have two poles on my property... One western power - with Wayleave One Openreach - which I have just found out has no wayleave. (and openreach are playing hardball) Question: The Openreach overhead wire goes from thier pole and onto the Western power pole. If Western power is paying me for...
  5. F

    Squealing High Capacity Water Filter

    Yup... it is the Screwfix 16747. And contary to the first suggestion, it is meant for whole house (see attached picture). Sadly I need whole house protection as we have had issues over time with crud comming through the mains and clogging up shower/tap filters. Alas it wasn't a seal issue...
  6. F

    Squealing High Capacity Water Filter

    Hi, Not sure if it is my 15mm plumbing... but I installed a BWT high capacity water filter (just after the main stop cock) and it is causing massive squealing on any water use By Squealing I mean a high pitched squeal each time water is turned off... and if water is flowing slowly. Luckily...
  7. F

    Power Pole removal

    I have become a bit stuck with the process of trying to get a couple of Western power Poles removed from my land. The Good Got in touch with WP and they have given me an itemised quote to remove the poles. Great The Not so good The poles also carry Openreach telecoms, the quote made no...
  8. F

    New Extension - Cert for building Regs required

    Yes! Just to update, as suggested I phoned planning a claimed innocence. They said they would accept an EICR. It was a bit of a challange, the first 2-3 sparky's I called wouldn't do an EICR on work they hadn't done, but i eventually found someone who peformed an EICR. Got cert and gave it to...
  9. F

    Greenstar 30i Boiling loosing pressure (wierd)

    Just a quick update... The Boiler is now fixed. It was the expansion vessel (and other parts needed replacing). The problem was caused by a massive amount of sludge... in fact when the old expansion vessel was taken out despite it being empty of water it was like lifting a Gold Bar! I am...
  10. F

    Greenstar 30i Boiling loosing pressure (wierd)

    I understand what you are saying and thats what i did before, but without the boiler having an issue when the he arrives its obviously difficult to find an issue. I even have many video recordings of the boiler working perfectly as I was trying to get a video of the fault but it happens so...
  11. F

    Greenstar 30i Boiling loosing pressure (wierd)

    Thanks... I did have an engineer in for the intemittant hot water issue before the pressure issue started. The bolier checked out ok and with no way to duplicate the issue there was nothing to fix. They were really good about it and didn't charge me but not sure how I fault chase this one... any...
  12. F

    Greenstar 30i Boiling loosing pressure (wierd)

    Update... Finally just tried the schrader valve and it is indeed Niagra falls, which i guess it need to get someone in to get the expansion vessel replaced. Question... Can I ask a 2nd part to this question to see if I also have a 2nd issue (or confirm the issue is related)...
  13. F

    Greenstar 30i Boiling loosing pressure (wierd)

    If it is the vessel... isn't that a bad sign that it suddenly went without the system being touched?
  14. F

    Greenstar 30i Boiling loosing pressure (wierd)

    Funny you should say that, before today I would have said no but during today I noticed that heating went from a standing 1.9 Bar (overnight pressure test) to 3.5 bar 20 mins after the heating went on... obviously the PRV was dripping at that point. I don't know if that is total coinsidence...
  15. F

    Greenstar 30i Boiling loosing pressure (wierd)

    Thanks I will check out the expansion vessel next