    Shower pump replacement

    No problem just pumps thanks for the help.
  2. G

    Shower pump replacement

    Apologies just checked the hot water is from the top of the hot cylinder and then splits at the top to feed the two showers.
  3. G

    Shower pump replacement

    Hello, Just checked and we have been in the property for 7 years and they were installed by the previous owners. Yes I thought the universal may be the way to go so thanks for that feedback. So the pumps have their own cold and hot feeds in 22mm, this drops down to 15mm for the flexible...
  4. G

    Shower pump replacement

    Hello just pumps, The leaks have developed at the flexible connections (pump inlet). I realise that I could look to replace the hoses but I also have an issue of having to drop the shower head to have the pumps operate and I am looking to replace them (if they are original install they have been...
  5. G

    Shower pump replacement

    Hello all, I have two Salamander CT50 1.5 bar shower pumps installed in my loft for the main bathroom shower and ensuite. My system is vented and the distance between the bottom of the cold water tank in the loft and the shower heads is around the 600mm mark, probably a little less. The pumps...
  6. G

    Smeg integrated fridge freezer temperature problem

    Thanks for the advice RED1990, there is a screw behind the switch for the light. I had previously gently pulled this back, to see if I could work out the internal arrangement, why they make these things so difficult to work on is beyond me. Thanks again
  7. G

    Smeg integrated fridge freezer temperature problem

    The control is in the fridge compartment range 1 to 7, no matter the position will only chill to 10 degrees. The compressor does not run all the time, it seem to work just not across the full temperature range. I had thought thermostat, but was not sure. Thanks for the reply it is appreciated...
  8. G

    Smeg integrated fridge freezer temperature problem

    Hello all, I have moved into a flat with a Smeg integrated fridge freezer. The problem is the fridge is "warm" (according to an independent thermometer) Freezer is fine and the compressor does kick in when cooling is required. Regardless of the position of the stat the temperature does not...
  9. G

    Interchangeable

    They are TRV's controlled by an actuator and their own wireless thermostat. They are available on two web sites (conrad electronics and housetech solutions) I think they are imported from Germany? Then branded with their own logo. Other than the logo it appears they are the same
  10. G

    Interchangeable

    -------------------------------------------------------------------------------- Would anyone know if Conrad electronics FS20 units are interchangeable with Housetech HH units? Regards
  11. G

    wilo smart pump

    All, The original install of my bypass system on the central heating is in 15mm branched off the 22mm with a standard gate valve. Do I fit a 15mm auto bypass. Do I rip it out and fit 22mm pipe and auto bypass. Or install a wilo smart pump which I believe does not require a bypass, my...
  12. G

    Which Boiler?

    D_Hailsham Thanks for the info. Is there a difference from a relabilty/maintenance/servicing point of view between a combi and a standard condensing boiler??
  13. G

    Which Boiler?

    All, I will be replacing my old oil boiler with an oil condensing unit. Any advice on makes would be appreciated. Would a condensing combi boiler be worth considering?
  14. G

    central heating choices

    Hello All, I recently raised the issue of replacing my ten year old Boulter 50/70 classic oil fired boiler and was told that I could expect annual savings of around 10-15%. The boiler has been serviced every year and I am wondering if looking at the central heating in sections would make...
  15. G

    Boiler replacement

    Thanks ianniann