Recent content by higgie21

  1. H

    40mm PVC underground

    Hi I have built a small outbuilding and was looking to fit a toilet My main sewer is at the front of the house and i would like to run a 40mm PVC solvent welded pipe from a Macerator,then run a 40mm PVC pipe under ground, the run of pipe would be 6-7 meters meters and then connect into...
  2. H

    monobloc tap repair

    thank you
  3. H

    monobloc tap repair

    Hi Just wondering if you can help I have this type of monobloc tap and the lever handle is lose cold side, how do you take it of to tighten the retaining screw?? Thank you
  4. H

    fitted cooker

    Hi Fitting a integrated oven, I have solid 40mm wood worktops Do i need any heat shields around or above the cooker, i have a induction hob fitted above the over as well I also have a problem with the oven not fitting, it is too high about 40mm when fitted into the over carcase The...
  5. H

    cooker

    So use a 32MCB, the 10mm cable leave that where it is, and from the 45amp cooker switch run down to a double cooker connection and use 4mm to the hob and oven Sounds like a plan Thank you
  6. H

    cooker

    Hi All Got the cooker and hob now the hob is a induction one so the power is 7200watts, 30 amps and the oven is 4900 watts, 20 amps So if i do diversty it works out both on the same MCB 22amps But if i do put in a 45amp or 50amp MCB i should be coved to put both on the same MCB And the...
  7. H

    worktops solid wood

    Ok, i thought you used the jig But i still would have to use the clamp bolts to pull the worktops together and biscuit joint them together and use a good glue Also use the router to do the square edges Thank you
  8. H

    worktops solid wood

    Hi I am fitting solid wood worktops in my kitchen, Just need a few pointers Do i just use a normal worktop jig to do the joints, And do you lot put oil on the bottom as well as the top to coat both sides I have only one join to do, and i was just going to buy a cheap jig and a good...
  9. H

    cooker

    thank you for your help and info
  10. H

    cooker

    Hi Not got them yet, the ones i have seen Oven is 20Amps Hob works out about 30Amps So that will mean they will have to be tied together So maybe this is wrong but supply to a junction box via 45amp DP switch then split to oven and hob Or is there any way or do i have to have two different...
  11. H

    cooker

    Hi all I am fitting out a new kitchen, Just a quick one, i am fitting a integrated oven with grill And a 4 ring fitted hob I have a 30amp supply that goes to a free standing cooker just now, but when i fit the new cooker and hob How does this 2 get wired up Does the integrated over get...
  12. H

    Double light switch

    Hi Guys, Need a little help here I have some under 240v cabinet lights and some 12v kickerboard lights to wire up I want to control both lights with a double light switch I am going to take a feed from the lighting circuit down to a double light switch And do a live switch and...
  13. H

    shower tray

    There is already a electric shower over the bath sory forgot to say so i am just going to balnk off the hot&cold feed for the bath What is the distance from the centre of the pan connector to the branch connection of your new 40/50mm shower waste? It would be around 220mm- 250mm from...
  14. H

    shower tray

    Hi lads Looking at removing the bath and fitting a shower tray Few questions for you Going to remove the bath and do away with it and fit a shower tray Do i just fit a isolation valves and blank hot and cold water supply for old bath under the floor The new show tray waste is...
  15. H

    Double pole 100amp breaker

    more photos