Recent content by HomerSimpson

  1. H

    Stitch drill or Diamond Core drill?

    I need to cut 4", 5" & 6" diameter extractor fan outlet holes in standard cavity walls. (inside = soft celcon, outside = fairly soft facing brick). I was going to hire diamond core drills but the 3 sizes makes it quite expensive. Has anyone had any experience of marking the circle and...
  2. H

    Does a kitchen extractor fan also need an air inlet?

    I'm about to fit a large 540m3/hr extractor unit over the cooker and the intallation manual says that I need to have a 500cm2 air inlet in the room to balance the pressure. I understand the theory of this and would be happy to do it if necessary but I just wondered if anyone actually bothered in...
  3. H

    Downlighter close to joist...

    When planning the downlighter positions in our new kitchen to coincide with worktops etc, i have found that one will be nearly touching a joist (the others are all thankfully mid-joist). I've heard that there some fireproof type of plasterboard...would a piece of this be sufficient to...
  4. H

    Do toilets need to be fed Cold Softened Water?

    Thanks for the replies all. Given that we're still at first fix, I'll probably get the plumber to run both soft and hard cold supplies to the bathrooms. One other question I have is that in the water softener literature it says it uses up to 63 litres of water to regenerate. Does this happen...
  5. H

    Do toilets need to be fed Cold Softened Water?

    I'm about to have a water softener installed in our extension and had a question as to whether toilets needed cold softened water or not? It seems to me that they would use up a high volume of softened water unnecessarily? Comments please... My intention was to connect the rest as...
  6. H

    Soundproofing of internal stud walls

    I have built stud walls upstairs in our new extension using 89mm CLS and plan to clad them in 12.5mm plasterboard plus a skim. To meet Part E for soundproofing (and thermal) I was just going to fill them using the standard 100mm Crown wool on a roll. I then started to research all the...
  7. H

    Internal Door Liner Height

    Thanks for the reply...much appreciated
  8. H

    Soundproofing of internal stud walls

    I have built stud walls upstairs in our new extension using 89mm CLS and plan to clad them in 12.5mm plasterboard plus a skim. To meet Part E for soundproofing (and thermal) I was just going to fill them using the standard 100mm Crown wool on a roll. I then started to research all the...
  9. H

    Internal Door Liner Height

    I'm fitting some standard door liner kits (the type morticed for both 27" and 30"). Silly question but what should the height be from bare floorboards to the underside of the head? They come in at 2005mm which I'm assuming needs trimming as standard doors are 1981mm. How much clearance...
  10. H

    Which make of Water Softener would you recommend?

    I'm looking to buy a water softener and have tried researching it but there doesn't seem to be one make that stands out. Which make would you recommend for a five bedroom house? Also, are the ones from B&Q any good...they seem dear enough at £450
  11. H

    Can joists be drilled to take bathroom plastic waste pipes?

    Thanks Paul...you've just saved me from lots of hassle! I should have realised that I wouldn't have been able to thread a rigid pipe through the holes anyway. Thank you...I'm glad I asked now.
  12. H

    Can joists be drilled to take bathroom plastic waste pipes?

    I'm sure this has been asked and answered before but I couldn't find it on search. My joists run the wrong way for our new proposed bathroom layout. Is it permissable to drill the joists with a hole saw to take 32mm or even 40mm plastic waste pipes? or do I have to build a boxed-in skirting...
  13. H

    Plaster 'skim' thickness / door-lining

    What is the usual thickness of a plaster 'skim' on standard plasterboard? I need to know this to calculate the size of my door linings as I'm using 89mm CLS studwork with 12.5mm plasterboard each side. The door lining will presumably be 114mm + 2 'skims' in thickness. Is there a standard...
  14. H

    Soil & Vent Breather Pipe

    Rather than run a 110mm soil pipe up the corner of my (upstairs) bathroom wall to connect with a Drago intake valve in the loft, could I not use 40mm drain pipe inside the studwork which then tees back into the Drago valve via a 110mm fitting once back in the loft? The alternative I suppose...
  15. H

    Soakaways and drainage

    I have quite a few questions on this subject so here goes... Q1. I am building a wide gravel drive on a slope with a hardcore sub-base which leads down to my house / garage. How much drainage does this need or will the water simply soak in across the general area? Q2. I was thinking of...
Back