Recent content by irbie09

  1. I

    using british gas

    The entire tread was funny but this tops it all, are you BG's accountant? or were all these all a guess?
  2. I

    Glow worm compact 80E - how old?

    Ceased production in Dec 2002,no where near 15 years old i would guess
  3. I

    wiring diagram to wire stat to vokera maxin 24e boiler

    your receiver will have a permanent live & neutral, these come from the mains/fuse spur or from the L/N on boiler. you need to remove the link on 1 and 2 on the boiler take a wire from terminal 1 on your boiler to the com terminal of your stat. take a wire from terminal 2 on your boiler...
  4. I

    Ariston eurocombiA/23 MFFI

    The control knob spindle on the central heating had worn out and was not turning up the aperture on the PCB, easy fix was swapping with the hot water spindle as this is always set to maximum. Thanks for the replys
  5. I

    Ariston eurocombiA/23 MFFI

    Hello, has anyone come across this fault,hot water works fine, heating gets to 40 deg on the display lights and shuts down,cools and repeats process. The diverter valve has been checked, the water quality is good, the sensor has been replaced, the boiler will stay on with a spare sensor...
Back