Recent content by jcb208

  1. J

    Texecom Smartcom flashing blue cloud led

    Thanks sort of got it up and running by rebooting the panel but the app is asking me for installer ID which i dont have
  2. J

    Texecom Smartcom flashing blue cloud led

    Sorry typo 127.0.0.251 is what I set at.I have reset the smartcom and now it wont connect at all to wintex using ethernet. I think its too old as it is an early version ,What's the cost to have an up to date texecom panel fitted with new sounder and programmed ,I have 7 working zones in the...
  3. J

    Texecom Smartcom flashing blue cloud led

    Thanks I set it to 127.0.0.51 it still wont generate an app code
  4. J

    Texecom Smartcom flashing blue cloud led

    As I have not got a lot of experience DIY installed the panel 20 years ago and added smartcom later and it was working ,enclosed screen shots If you can please tell me if they are correct
  5. J

    Texecom Smartcom flashing blue cloud led

    HI experts, going back to this fault my system had to be reset and since when trying to generate an app code to connect the phone app I get the same error "incorrect config call terminated" and UDL lockout on the keypad. I know the UDL password is default 1234 and set correctly and I can...
  6. J

    Installing Texecom Connect Smartcom

    Lol took me ages to get it working in 2013 my brain is older now :D Wintex has not got the smartcom config saved just the zones,part arms and codes with tags which are in use.Still got to work out how to set up the extra com port that is supplied with smartcom yet as the panel only has the 2...
  7. J

    Installing Texecom Connect Smartcom

    My mistake installed it in 2013 just checked the dates of questions I asked on this forum back then.It is an elite 24 not wireless with 2 com ports, so will default tomorrow encase any thing goes wrong
  8. J

    Installing Texecom Connect Smartcom

    Hi I installed the alarm panel Elite24 over 10 years ago , and have decided to add smartcom,Flashed the firmware from 2.01 to 5.02 and connected smartcom using a ethernet cable.Problem is I can not get it to work even though I followed the youtube tutorial,It says incorrect config call...
  9. J

    Painting Plasterboard

    No need to go mad with the water,add about 20% water max for the 1st coat and then 2 more coats with 10% water added should give a good finish
  10. J

    Wallpaper help

    Nope unless you want to strip the lot off and start again.The lining paper gaps must of been quite big for them to show through the finished paper.Sorry not what you want to hear but I cant think of an easy solution
  11. J

    misting with vinyl silk emulsion

    Yes not a good idea but proberbly will not cause you any problems especially If it was old plaster.Even new plaster theres no rule that says it will all peel off.9 times out of 10 it will bond fine
  12. J

    Paint looks different where cracks were filled in

    If they used tetrion to fill that flashes really bad on emulsion
  13. J

    Wall paper paste...

    Will not last very long tends to go watery after a couple of days
  14. J

    MDF, Priming, Undercoat, Emulsion and gloss question

    Not ideal but you can emulsion it.Best to use a water based primer undercoat as the edges will rub down better as it drys harder then emulsion
  15. J

    Getting Patchy results.....

    Have you checked the wall is dry with a moisture meter as that looks like damp plaster stopping the paint from fully drying out
Back
Top