Recent content by kevoffthetee

  1. K

    Boiler mfrs wireless roomstat?

    Just wondering if anyone would use a manufacturers wireless roomstat over a third party model. I had a main eco elite combi installed yesterday and I'm thinking now of a wireless roomstat as the daft bugger heating engineer forgot to put the 24hr mech timer in. I didn't complain and make him...
  2. K

    Old combi scrap value

    Just wondering what you might get if you weighed your old combi in. Just thinking it'll help pay for an rf room stat on a new boiler
  3. K

    Best long term cleaner/inhibitor

    I'm just after a little advice on inhibitors. Are there any better than others. I've looked at the sentinel x100 and x200. I know a new system shouldn't be noisy but if it has all of the benefits of x100 plus more without any negatives then it might be something I consider. The like of...
  4. K

    Combi boiler replacement

    Thanks for the suggestion, I'll look into it. Has anyone had experiences of the Glow-worm easicom range? a 24kw for just over £600 inc vat with clock, std flue and stainless hex
  5. K

    Combi boiler replacement

    Thanks dan Did you pass whilst with BG or have they paid you for sole right to your gas safe qualification. What happens if someone qualified before they joined BG I'm not sure on his standing, only that he works for BG
  6. K

    Combi boiler replacement

    Thanks for the replies. I didn't realise that my neighbour wouldn't be registered unless working for BG, I thought it was the person that was registered. Bloody hell, that means they could send anyone to your door
  7. K

    Combi boiler replacement

    Sorry to post again but my previous post regarding combi boiler recommendations was hijacked by people arguing with joe90 I'm after a budget boiler as I'm moving I'm the next few years but have taken some tips from the forum into consideration, for example a stainless primary heat exchanger...
  8. K

    Main Eco elite heat excahnger

    Thanks for the replies. I'm going to have to organise this weekend as although the issue is intermittent, the boiler is off again and I'm now fed up and have left a message for the installer Are there any others on the same budget (or not much more) as the main but with a stainless heat...
  9. K

    Main Eco elite heat excahnger

    Morning all, I'd like to know if the plate heat exchanger on the main Eco elite 25 combi is stainless steel or not. I'm in the market for a budget boiler for my 2up 2down mid terrace and after reading on the forum about things to look out for I can't find this out from the info provided for...
  10. K

    Can a 3 way valve be stuck in neutral?

    Hi Ian, I do appreciate the help and since your advice that it was the pump over run I haven't posed any more suggestions or questions about other parts. All I have done is give feedback on how it's going. The quote above is a response to how long the pump runs once the burner goes out. The...
  11. K

    Can a 3 way valve be stuck in neutral?

    No a direct replacement for the original grundfos. He has been around again today and went over everything he has done so far. Before he started he thought the pump may still be the issue but that it could be a bad electrical connection. He disconnected everything to the pcb board, checked...
  12. K

    Can a 3 way valve be stuck in neutral?

    I didn't know mackems were called little elf's, now I'm really confused ;)
  13. K

    Can a 3 way valve be stuck in neutral?

    Just to confirm, the boiler fired up and when the burner switched off in ch mode the pump ran on for 2.5 mins
  14. K

    Will an 8 Ltr expansion vessel do (with video)

    Just to confirm, the boiler fired up this morning and when the burner cut out in ch mode the pump ran for 2.5 mins Given this I'd think the pump only cuts out with the burner following the pressure and noise problem so I'm back to square one
  15. K

    Can a 3 way valve be stuck in neutral?

    Just to let you know the boiler has stayed on when i turned the boiler on this morning and the ch is heating up. i'll check for the pump over run once the system is up to temp. I believe / hope the pump only kicks out at the same time as the burner when there is a problem and the boiler cuts...