    Help needed please with CH problem

    sounds like you haven't wires up your components properley!!!! :(
  2. L

    Rumbling Pump

    boiler will still run on your boiler and if pump doesn't circulate water, will cause the water to make a kettling" noise inside the heat exchanger and probably cause an ejection from the vent pipe ino the F & E cistern. Unless your boiler has an overheat stat.
  3. L

    Modern room stats?

    Do modern room stat's / digital room stats that do not require the neutral wire to make an anticiaptor work - have a resistor instead which is operated by a battery? i take it the resistor is a thermistor actually though? Just been bugging me today as I was thinking of chainging but not...
  4. L

    new shower mixer/dial type

    I have a manual shower over my bath, a dial type (round). It has separate hot and cold feeds to it. The pipes are concealed in the airing cupboard just behind it and the dial is flush on the tiles. It is about 12 years old now and drips a bit under the control wheel. If I am to change it...
  5. L

    a Tap Stat?!

    thanks for the link! so basically they are to give extra protection to hot water draw offs (like a thermostatic mixer valve). only thing is they all seem to be 15mm connections and most primary connections to and from the hwsv are 22mm!!
  6. L

    a Tap Stat?!

    What exactly is a "TAP STAT"? and where would they be fitted and their purpose? I have heard them mentioned in some posts on this site but have never seen one and never read about one either!??
  7. L

    Noisy Ball Valve and Yellow water!

    Part 2 are best type now for fitting to cold water tanks in lofts. part 1 hae a high backflow risk and are not permitted.
  8. L

    backfilling via vent pipe (water level) .... ??

    as a matter of interest, on both the cwcs and f & e vent pipes ..... maybe as mtnioned above water leaks out overflow until the normal amount of dry head is achieved again?!
  9. L

    backfilling via vent pipe (water level) .... ??

    here's one - when backfilling a system (to get air out via the vent) - after doing this how does the level of water in the vent pipe level out again to its original level?!! the normal level is supposed to be the same as that of the level of water in the cold water tank .... how is this...
  10. L

    Pros and cons ref. siphon or flap vave in WC cistern?

    i have found that drop valves (push button) after a while dont give a very good / clean flush. and siphons are like;y to be longer lasting. also with a b & q push button (the type with the plastic leve linking the valve to the button ) you can fit these on any toilet - remove the old handle...
  11. L

    Size of CWST's for shower and cyl only?

    yeah just fit a standard 50 gallon tank. i have never seen a 25 gallon tank used for a f & e cistern though - more like a 4 gallon tank.
  12. L

    HW Cylinder stat failure / IH stat failure?

    the reason i ask is as i fitted a new thermostat on my cylinder about 5 months ago - and tested it (it turned on and off properley). but if the sensor part blew and didn't shut off the supply at 60 degrees (which i have set it at) - how would i know? The water from my hot tap is hot (i cant...
  13. L

    HW Cylinder stat failure / IH stat failure?

    Just a question (probably sounds dumb) :) but to put my mind at ease after reading through some posts on here lately. If a cylinder stat or an immerson heater thermostat fail (on an opne vented system) - the water will probably boil (unless the thermostat on the immersion heater was a newer...
  14. L

    Surrey flange - pipework to mixer shower...

    just a quick question/query - when fitting a surrey flange at the top of the hot water cylinder and running the pipe to a mixer shower (no pump just straight to the mixer) - does the pipe run have to be as straight as possible, or is a 45 degree bend downwards allowed? i don't want an airlock...
  15. L

    buying/installing a new sink?

    i believe most sinks are of standard size ranges and surely a straight swap can be done without any extra cutting? my point was, how are plastic sinks tightened to the worktop in general? surely they are not just pushed in??