Recent content by Markyb250

  1. M

    Celotex Ga4100 Rigid Board for Underfloor Heating

    Thanks, as their blurb avoids adding ufh heating in the list of uses, I didn't know if there was a reason or if it was them pushing you toward the ufh range they have.
  2. M

    Celotex Ga4100 Rigid Board for Underfloor Heating

    Hi all, So I have some spare GA4100 celotex after using it for between the roof rafters. I should have enough remaining to provide a 100mm installation floor base and 75mm screed. Is GA4100 safe to use with ufh? Will the compression be too weak or will the foil cause issues? Ideally I would...
  3. M

    Inner leaf damp proof too high?

    Hi all, hope you are well. We currently have an extension underway and it appears the dpm will be a good bit higher than the finished floor level (almost a block higher). I assume they have got this wrong due to sloping ground and having to add a cavity tray. The builder is no longer with us...
  4. M

    Underfloor Heating - Multiple JG Speedfit Manifold Leaks

    Hi all, I hope you are well. I have recently moved into a property with underfloor heating. When we moved in there was no water pressure in the boiler and we noticed it only took a few weeks after filling up to drop to zero. After investigating we can see the JG Manifold is leaking in several...
  5. M

    How to Close a New Build Cavity - Bi-Fold Doors

    Thank Thanks 23vc. Currently the slab is around 100mm below the inner blocks, so it would be 100mm Celotex and 75mm screed with underfloor in there. Could a solution be to add another 100mm in blocks to align inner and outer and fill the cavity with concrete around the door area? I assume this...
  6. M

    How to Close a New Build Cavity - Bi-Fold Doors

    Hi all, I hope you are well. I am looking for some advice on our extension and how to close our cavity floor to install a bi-fold door. Currently we have a 2.05m high by 2.0m wide area for the bi-folds. On the external wall is a layer of stone directly on the blocks which has a DPC and is...
  7. M

    Cowboy Builders - Roof Height Issue

    It has been like that since at least 2012 when it was converted from an old farm house, we get on with the neighbours, so happy to tell them what sort of issues they can expect. That part is currently just a storage area, barn like almost. You can see light coming through the roof in that area...
  8. M

    Cowboy Builders - Roof Height Issue

    Thanks for the feedback, loving the paint arrows . This is reassuring. There is no flashing at the back as they just legged it after we asked them to sort. However it sounds like we can recover it? Out of interest what did you spot on our neighbours property with the wtf comment. The huge...
  9. M

    Wood Burner Party Wall getting hot

    If it concerns you, you can always get them to install a heat shield at the back of their fire. Apart from the extension from the heat in the wall or the risk of children touching it, the free heat is a big bonus.
  10. M

    Cowboy Builders - Roof Height Issue

    Hi all, I hope all is good with everyone. Looking for some advice, as the extension we build to give our child his own room has sadly been hit with some cowboy builders. (We got references, recommendations, saw their previous work and they were not cheap) In a nut shell they have built the...
  11. M

    Wall cracks in 7 year old barn conversion

    Hi all, I hope you are well. Just looking for anyone's opinion on these cracks. Both cracks have been here since we moved in and after filling they have recently began to open again 18 months on. The first crack is against the join in the wall and runs vertical up the wall between the join. It...