Recent content by nero44

  1. N

    Decorators - how to make good

    Thanks @Wayners really helpful. I used to have these sanding sponges, but they really become rubbish with some real use, i.e. anything beyond a diy art project.. What would you say for the corner/edge where paper/tape has torn? It actually has torn off on several locations further up the...
  2. N

    Decorators - how to make good

    Hello Decorators, I have removed some MDF shelving in my alcove. On the left side is an unused/inactive chimney and right side is just regular wall, where you can also see some shelving on the other side still to be tacked. Anyhow, the shelves were actually a box structure and when removing...
  3. N

    Stop birds nesting under solar panels

    Solaskirts are the best, but very expensive. Mesh still better than these plastic birdblocker. I had these and after 18 month it came loose at three locations. Invested in Solaskirts now and so far all good.
  4. N

    Puzzling energy rating

    I think they are rolling out these changes to all electrical appliances. I think it makes sense for larger more complex appliances (white goods+TVs etc), maybe not so much for a string of christmas lights... But then common sense should apply and and you should not worry about it. For more...
  5. N

    Gas Supply Pipe blocking crawlspace

    Post mortem: I did end up calling Cadent for a quote to have the gas supply re-routed properly. I.e. directly from the main supply pipe under the pavement to my meter in my front garden and I am glad I did.... when they showed up to do the works one of their surveyors detected small amount of...
  6. N

    yet another earthing/bonding thread...

    Just stumbled across this old efixx video on this topic. Would've never assumed that a line fault on my neighbor's incoming supply could bring diverted neutral current to my house etc. Very interesting. So from this point of view moving to non-conductive supply pipes is safer for my house to...
  7. N

    yet another earthing/bonding thread...

    Thanks, but just to be perfectly clear... I also do not need to remove the existing bonding following supply pipe replacement correct? i.e. no harm leaving it in situ.
  8. N

    yet another earthing/bonding thread...

    Dear Sparkies, I have two EICRs from my house, the first/older one says I have TN-C-S and the second/newer one (post CU & Meter replacement) says TN-S. The 100a incoming supply was not amended. The first EICR was commissioned by the previous owner via an estate agent for a rental... the second...
  9. N

    Inbuild speaker system in kitchen ceiling

    you are probably right. Just peaked at my neighbour's plan whose house is a copy paste of mine. It appears their design shows 4 in total. two top top bottom. Probably a better way and doable if everything will be rebuilt. They installed passive speakers to be hooked up with Sonos amps. Some...
  10. N

    Inbuild speaker system in kitchen ceiling

    yes that would be the next step. I expect the kitchen to be roughly 4.5m x 6.5/7m depending on planning permission. So a fairly rectangular setup. It is likely that speakers will be more used during cooking and general social gathering, rather than when seated at dining area. Again it doesn't...
  11. N

    Inbuild speaker system in kitchen ceiling

    Thanks @Lucid very good content and lots to think about! Before posting, I was actually looking at something like QAcoustics and thought that this might fit quite well for my needs. The reason I thought a wall controller is handy is of course part aesthetics but also the idea that any person in...
  12. N

    Inbuild speaker system in kitchen ceiling

    Thanks all, very useful info. Kitchen design is far from final, need to agree with the mrs.... but it seems active speakers bit if a faff and risk putting cheap components... so passive, with cable to a location (still to be finalised) and then any decent amp to feed it with BT receiver seems...
  13. N

    Inbuild speaker system in kitchen ceiling

    Thanks. Speakers therefore are passive? i.e. they just need audio cables from the amp to the speakers, no power required? So you are saying I don't really need a wall control unit, but just an Amp somewhere which connects to a BT receiver? And then everything is effectively controlled via...
  14. N

    Inbuild speaker system in kitchen ceiling

    Hello Everybody, planning a full kitchen refurb next year and would like to have some ceiling speakers. It should be a relatively simple system. Two speakers built into the ceiling, somewhere there needs to be an amp, and then a wall mounted control system. In its simplest form, it should have...
  15. N

    Scam ??

    same, but it's such a high traffic area the gates are practically almost always open... so quite easy to get out w/out... but then .. shoplifting in central London.. I think nobody is surprised...
Back
Top