Recent content by peterniss

  1. P

    GU10 Pendant

    Thanks very much Eric. I'll get them changed to BC holders. Can't find any GLS lamps with those GU10 type caps. A government own goal !!
  2. P

    GU10 Pendant

    Hi all, In my mum's house the bedrooms have ceiling light pendant fittings with GU10 lamp holders. The other rooms have standard BC lamp holders. It seems that GU10 GLS bulbs are not widely available so looking to get the bedroom pendants changed to BC. But before doing that just wondering why...
  3. P

    Geberit Flush Volume Adjustment

    Out of interest, Rigidraider, did you find out how they work ?
  4. P

    Geberit Flush Volume Adjustment

    Thanks Fluffster. The older one and the recent one both use the same type of flush plate -- two buttons with rods, not pneumatic. On the older one, on both short and long flush, the flush continues after releasing button, but flushes more on the long flush, as expected. But on the newer one it...
  5. P

    Geberit Flush Volume Adjustment

    Can anybody advise how to adjust the flush volume on Geberit UP200 concealed cistern? We have one fitted recently, and when using the short flush button it stops flushing pretty much as soon as the button is released. Another that was fitted approx 6 years ago flushes much longer on short flush...
  6. P

    Miele W828

    Finally, success here with our W827 as well. I removed the brush holder module on the front of the module to check out what it does, replaced it, paying special attention to the correct location of the 4 spade connectors, and checked out all the connections from the el200D end of the connectors...
  7. P

    Miele W828

    I have exactly the same problem as described by the various posters here with a Miele W827. I found that the fuse described was indeed blown, and the reverse direction relay not switching reliably. So I replaced both, reassembled, turned on ready to receive adoring congratulations from the wife...
  8. P

    Neutral or Acetoxy Silicone

    Looks like good stuff -- I will try this. cheers Pete
  9. P

    Neutral or Acetoxy Silicone

    I need to seal bottom of tiles to a plastic shower tray. I was on the point of doing so with Dow Corning 785 and noticed that on the list of stuff it sticks, plastic is not there. On looking at one of Dow Corning Datasheets it suggested an adhesion test for plastic substrates, which I have done...
  10. P

    Wall Mount Bath Filler

    I contacted the manufacturer, Barber Wilsons. They have improved the design of this so that the spout is on a wall plate mounting instead of being supported by the supply pipes. Also, instead of screw in, it now pushes on to a spigot with o-rings and fixed with grub screw -- really nicely done...
  11. P

    Aquapanel Joints

    Thanks for that Richard. Do you bed the reinforcing tape into tile adhesive on the surface of the boards? Any particular type of tile adhesive that should be used -- a recommended brand/type would be great if you can. Finally -- what do you use at corners between walls and wall to floor...
  12. P

    Aquapanel Joints

    I am planning to use Aquapanel around shower cubicle and above bath (Aquapanel on timber stud wall, and finished surface will be tiles). I am in two minds about the best way to do Aquapanel joints. Knauf produces two leaflets with two different guidances: one says to leave a 3mm gap then fill...
  13. P

    Wall Mount Bath Filler

    Many thanks for your replies Dextrous. There is a 4"/150mm gap (4x2 stud). I will look at a 1" BSP to 22mm straight, into a soldered 22mm tee. I am thinking because it's straight I can use it also to nip up to the back of the aquapanel to give more support (the spout is really heavy, and...
  14. P

    Wall Mount Bath Filler

    Having posted on choice of board for stud wall behind bath, I am now convinced to use Knauf Aquapanel. The threaded piece of tap filler is 38mm long (diagram at link below). I'll have 12.5 mm tile/adhesive + 12.5 mm board + 12 mm backnut, total 37 mm, which leaves no thread left to get the BSP...
  15. P

    Wall Mount Bath Filler

    The threaded section is part of the body of the filler spout, fixed tight in, not removable.
Back