    Builders details query

    yes its a steel hollow section with plate checked and there`s no insulation thrugh middle either
  2. S

    Builders details query

    Few queries on my builders work need clarification before i ask them: Timber joists infilling- Rear Extension builder has infilled between timbers with concrete block with no mortar yet my house which is around 7`s year old has mortar beds either side of blocks which is correct...
  3. S

    steel beam bowing

    thanks for comments see attached calcs
  4. S

    steel beam bowing

    it needs to take 4 course of blocks wood no the 2
  5. S

    steel beam bowing

    returns are 900mm no posts woody, flat rood only carried on internal leaf of beam external 900mm of parapet block wok
  6. S

    steel beam bowing

    will speak with structural tomorrow beam is UB254x102x22 with an 8mm welded bottom plate looks like the plate that is rotating only a beam has no flex really dont want too add a mid point post if i can help it. just measure ed of beam and looks like builders have installed correct beam.
  7. S

    steel beam bowing

    4 course of block above beam are required, might have to put a central pier in to stop the sag now not what we wanted but might rectifiy problem.
  8. S

    steel beam bowing

    7.5m opening beam i think is 254x 19
  9. S

    steel beam bowing

    the brickies have started loading out steel beams over patio opening on friday was in the garden today a look a bit off to the eye so measured this with a lazer level and tape and it would appear at the mid point its 20mm lower that the ends but only on the welded flat plate section not the UB...
  10. S

    steel beam

    do you need to bed steel beams onto concrete padstone or can they just go straight onto pads.
  11. S

    New door opening

  12. S

    New door opening

    i would like to opening in for an new external door way close to the corner of my existing house now that the rear single storey extension as been built, is there any guidance to say this is not allowed.
  13. S

    TIMBER JOIST

    .
  14. S

    TIMBER JOIST

    i have 2 questions related to flat roof joists. joists 4x2 400mm centres Q1: Can the joist sit directly on top of steel UB then block work either side and above or is a timber wall plate required? Q2: wall plate / leadger board connected to existing cavity wall, what size threaded rod is...
  15. S

    Trench Blocks 20mm out

    3 courses of Trench blocks have drifted inwards at the end of the run, shall i overhang inner blocks or bring everything in 20mm and reduce 100mm cavity to 80mm cavity is full fill batts ?