Hello - I would appreciate some advice - I have purchased a property (so I don't know the history) where there seems to have been a bit of a mess made to address the gap between the bottom of the tiles and shower tray - please see photos - I'm guessing there was a gap and someone has used some...
Hi all - thanks for your replies - I want to add some form of control to the bottom immersion as I think the amount of water heated during the nightime Economy 10 period (5 hours) will be sufficient for our hot water needs i.e. I don't think there is any need for the immersion to come on during...
I am having my direct unvented cylinder replaced shortly with a Heatrae Sadia Megaflo Eco 145dd. As part of this I want to have more control over the immersion heaters. I'm on an Economy 10 tariff and the current set up is a 1) dedicated Economy 10 circuit from a 16A breaker to a 20A DP switch...
I have recently screeded a concrete floor as it was uneven - I now want to tile it. I have some porcelain floor tiles - is it possible/sensible to lay the floor tiles with a building sand/cement (3:1) mix rather than use an expensive tile adhesive.
For your reference the room is very small...
I'm a keen DIYer but a novice with roofing work. I have a house circa 1915 (Edwardian) with a main roof tiled with rosemary tiles. I am just doing some repairs and wonder if anyone could help.
I have missing/damaged ridge tiles and missing roof tiles
- is it difficult/expensive to get good...
I have a small (2x2.5m) outhouse which I am converting to a utility room - it is single brick with a concrete floor the surface of which is only a couple of inches below the top of the damp proof course. I would like to ensure that there is no water penetration through the floor before tiling -...
Grateful if somebody could help.
I have a gravity fed DHW system (cold water tank/indirect vented cylinder) with a Worcester system boiler. No FE tank.
My trouble is with the hot water from all taps/showers-its at a trickle (about 1litre/min!!), the cold water outlets are all fed from...
I have a Wbosch system boiler with an indirect vented cylinder. I'm considering installing an unvented cylinder (santon/albion) to improve my DHW pressure. The problem I have is that my cold mains is entirely piped in 15mm copper (to replace this with 22mm would be too costly/disruptive). Severn...
Grateful if somebody could help.
I have a gravity fed DHW system (cold water tank/indirect vented cylinder) with a Worcester system boiler. No FE tank.
My trouble is with the hot water from all taps/showers-its at a trickle (about 1litre/min!!), the cold water outlets are all fed from the...
A question regarding a mystery overflow.
1st my system. I have a recently installed Worcester condensing system boiler. I have a normal vented HW cylinder and a CW storage tank. The FE tank has been removed when the system boiler was installed.
The boiler works fine - HW and CH are both...