Search results

  1. F

    First fixing waste pipe for vanity basin

    Could fit a normal waterless trap then just elbow up in the trap
  2. F

    First fixing waste pipe for vanity basin

    Would you sort of bring in around this height then double elbow?
  3. F

    First fixing waste pipe for vanity basin

    Thanks yes I think the best way maybe to bring the waste pipe in low and then use two elbows maybe a street elbow then an elbow. It's all in solvent.
  4. F

    First fixing waste pipe for vanity basin

    Can see extensions but there rigid. 25mm or 40mm could do with one that's adjustable
  5. F

    First fixing waste pipe for vanity basin

    It's come with this trap and I don't no the the exact finish floor. As floor is to go down this tile. Do they do an adjustable trap connector so I could come out abit low and use this.
  6. F

    Long length of 32mm solvent waste

    I have a solvent waste pipe to run for a basin. Due to space restraints upsizing to 40mm solvent is difficult. The pipe terminates in to a hopper. The total length would be around 4meters.. Anyone had to do similar before. Or likely to cause issues?
  7. F

    First fixing waste pipe for vanity basin

    What kind of trap would you put on it? Is 300mm a height that will the elbow on to a trap. Obviously I don't want to be too height or have to use a load of fittings after it exits the wall
  8. F

    First fixing waste pipe for vanity basin

    What's best to first fix the waste pipe for a vanity basin like this? Is it to run it the wall and elbow out?
  9. F

    Stixall Vs CT1

    Water sealing
  10. F

    Stixall Vs CT1

    Which it the best of these two products
  11. F

    Isolation valves for heating

    Are the hep2o isolation valves ok installed on C/H. I no the cheap brass ones leak from the o-rings after time. Thanks
  12. F

    3 inch stack

    That's the base the stack runs under the building to the drain at the back
  13. F

    3 inch stack

    4 inch pot waste
  14. F

    3 inch stack

    How would you replace this goes in to the ground below
  15. F

    3 inch stack

    I have a new toilet to connect to a 3 inch cast stack. It used to have a toilet connected on it before via Lead pipe. Would most recommend a new stack or connecting on to the 3 in branch of the stack collar. And converting to plastic.
  16. F

    Shower tray installation

    Should be cement board. So it would be cement board the Wales first. Then the tray
  17. F

    Shower tray installation

    When doing a bathroom. Do you usually fit the shower tray before or after plasterering?
  18. F

    Reusing JG Speedfit Fittings?

    Could you reuse the fitting but change the inners?
Back
Top